Chapter 6 Instruction Details
XBC E-Type Main Unit
6-307
Ver. 1
6.44.3 FWRITE
Instruction
Area available
Step
Flag
P M K
F
L
T
C
S
Z D.x R.x
Con
st.
U
N
D
R
Error
(F110)
Zero
(F111)
Carry
(F112)
FWRITE
S
O O O O O O O
-
O
-
-
O O
-
O O
2~3
-
-
-
D
-
-
-
O
-
-
-
-
-
-
-
-
-
-
-
-
Operand
Description
Data Size
S
Number of Data or Device
WORD
D
F1024 ~ F2047 area in F area
WORD
1) FWRITE
(1) Used to save temporary value in word of F1024~F2047 in Special Rely in F area. The value saved by
FWRITE is removed at Power OFF.
(2) Used to save the word data in area repectively when detecting external device Error or Warning.
2) Program Example
(1) If P00001 connected with external device is changed to On, data of ‘1234’ is witten in F1026 (_ANC_ERR)
and the detection request of external device Error flag becomes set. PLC operation status is changed to
Error status.
FWRITE
FWRITE
S
D
FWRITE 1234 F1026
P00001
FSET F10242
P