Chapter 8 Option Boards and Memory Module
XBC E-Type Main Unit
8-21
Ver. 1
8.8 Example using DC Input Board High-speed counter
1. High-speed counter setup
a. Select high-speed counter mode.
b. If you need ‘Preset’ function, input ‘Preset value’ and turn on ‘Preset Enable” bit.
c. Specify ‘Latch counter’ or ‘Up/Down counter’
d. Turn on ‘High-speed counter enable’ signal
2. Monitoring
a. You can check option board high-speed counter value by registering U9.2 (no.0 slot,
no.0 ch.) at variable monitoring window or program.
Set up high-speed counter mode
Input value to preset
Preset Enable signal ON
Turn on High-speed Counter Enable signal (No. 9 slot, No.0 ch) of input option board (XBO-DC04A)