Chapter 6 Instruction Details
XBC E-Type Main Unit
6-63
Ver. 1
6.15 End Instruction
6.15.1 END
Instruction
Area Available
Step
Flag
P M K F L T C S Z D.x R.x
Co
nst.
U N D R
Error
(F110)
Zero
(F111)
Carry
(F112)
END
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
-
-
-
1) END
(1) Displays Program End.
(2) Returns to 0000 Step after END Instruction is processed.
(3) END Instruction should be input last in program. If not used, Missing End Error will occur.
Remark
What is 1 scan?
As shown below; A cycle of Input Refresh
User Program Executed
Self Diagnosis
Output Refresh
is 1 scan.
END
END
Input Refresh
0000 LOAD
P00020
0001
AND
P00021
Self-diagnosis
Output refresh
Operation end of user program
1scan