Chapter 6 Instruction Details
XBC E-Type Main Unit
6-57
Ver. 1
6.13.3 RST
Instruction
Area Available
Step
Flag
P M K F L T C S Z D.x R.x
Co
nst.
U N D R
Error
(F110)
Zero
(F111)
Carry
(F112)
RST
D O O O - O O O -
- O -
- O -
-
-
1
-
-
-
Operand
Description
Data Type
D
Contact to keep Off state / Word device’s bit contact
BIT
1) RST
(1) If input condition is On, output is kept Off even when specified output contact is kept Off to make Input Off. If
specified output contact is Word device’s bit contact, its applicable bit should be 0.
2) Program Example
(1) Where the output state of P00060 & P00061 is checked and P00061 output is made Off when input condition
P00020 changes On
Off.
[Ladder Program] [Mnemonic Program]
·
[Time Chart]
P00020
P00021
P00060
P00061
OFF
OFF
OFF
OFF
ON
ON
ON
ON
RST
R
0
2
Step
Mnemonic
Operand
0
LOAD
P00020
1
OUT
P00060
2
LOAD
P00020
3
SET
P00061
4
LOAD
P00021
5
RST
P00061
4
P00020
P00020
P00021
P00060
S
P00061
R
P00061
Summary of Contents for XBC-DN10E