WavePro 7Zi
231
WP700Zi-OM-E-RevA
6.
To display an individual segment separately from the main channel display, select
Math
,
Math Setup
from
the menu bar, and choose a math trace to define as a Segment (in this case, we chose to define F1 as a
Segment of C2). As a source, use the channel that your serial data was acquired on (in this case Channel
2). To display the trace, check the
Trace On
checkbox. To select the segment to view, touch the
Select
tab and select a segment using the pop-up keypad or the front panel adjust knob.
7.
To view decoded data on the individual segment, set up the Decode to use the Math trace as the source
for Data (in this case F4 is the source). If you wish to change the segment that is decoded, just select a
new segment from the Math trace dialog (as shown in the preceding step).