Parameter
Description
Definition
Notes
(ltut)
percentage of its peak-to-
trough amplitude.
data.
Available with DDM2 option.
Standard in DDA-5005A.
Mathcad
(mcad)
Produces a parameter using
a user-specified Mathcad
function.
Available with XMAP and XDEV
option.
Standard in DDA-5005A.
Mathcad 2001i or later must be
loaded on the instrument.
MATLAB
Produces a parameter using
a user-specified MATLAB
function.
Available with XMAP and XDEV
option.
Standard in DDA-5005A,
WaveRunner 6000A, WaveMaster,
WavePro 7000A, and sampling
scopes
MATLAB must be loaded on the
instrument.
Maximum
(max)
Measures highest point in
waveform. Unlike top, does
not assume waveform has
two levels.
Highest value in
waveform between
cursors
Gives similar result when applied to
time domain waveform or histogram
of data of same waveform. But with
histograms, result may include
contributions from more than one
acquisition. Computes horizontal
axis location of rightmost non-zero
bin of histogram -- not to be
confused with maxp.
Standard parameter.
Mean
Average of data for time
domain waveform. Computed
as centroid of distribution for
a histogram of the data
values.
Average of data
Gives similar result when applied to
time domain waveform or histogram
of data of same waveform. But with
histograms, result may include
contributions from more than one
acquisition.
Standard parameter.
Median
The average of base and top
values.
Average of
Base
and
Top
. Standard parameter.
Minimum
(min)
Measures the lowest point in
a waveform. Unlike base,
does not assume waveform
has two levels.
Lowest value in waveform
between cursors
Gives similar result when applied to
time domain waveform or histogram
of data of same waveform. But with
histograms, result may include
contributions from more than one
acquisition.
Standard parameter.
Nb Phase
(nbph)
Provides a measurement of
the phase at a specific
frequency of a waveform
(narrow band).
Available with DDM2, XMATH,
SDA, and XMAP options.
Standard in DDA-5005A and
SDA100G scopes.
Nb Power
(nbpw)
Provides a measurement of
the power at a specific
Available with DDM2, XMATH,
PMA2, SDA, and XMAP options.
Summary of Contents for DDA 7 Zi series
Page 1: ...Operator s Manual WavePro SDA and DDA 7 Zi Series Oscilloscopes ...
Page 2: ... L R R H HUD RU D D ...
Page 41: ...Operator s Manual WP700Zi OM E RevA 40 The detachable WavePro Zi front panel ...
Page 376: ...WavePro 7Zi 375 WP700Zi OM E RevA Absolute Offset Relative ...
Page 439: ...Operator s Manual WP700Zi OM E RevA 438 ...
Page 440: ...WavePro 7Zi 439 WP700Zi OM E RevA ...
Page 544: ...Thank you for purchasing a WavePro SDA or DDA 7 Zi Oscilloscope ...