2H0/2HZ
1-3-57
U250
Setting the maintenance cycle
Description
Displays and changes the maintenance cycle.
Purpose
To check and change the maintenance cycle.
Method
Press the start key. The currently set maintenance cycle is displayed.
Setting
1. Change the setting using the +/- or numeric keys.
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U251
Checking/clearing the maintenance count
Description
Displays, clears and changes the maintenance count.
Purpose
To check the maintenance count. Also to clear the count during maintenance service.
Method
Press the start key. The maintenance count is displayed.
Clearing
1. Press the clear key.
2. Press the start key. The count is cleared.
Setting
1. Enter a count using the +/- or numeric keys.
2. Press the start key. The count is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Description
Setting range
Initial setting
Maintenance cycle
0 to 9999999
300000
Summary of Contents for KM-2560
Page 1: ...SERVICE MANUAL Published in April 2008 842H0112 2H0SM062 Rev 2 KM 2560 KM 3060 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 14: ...2H0 2HZ This page is intentionally left blank ...
Page 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank ...
Page 36: ...2H0 2HZ 2 1 2 16 This page is intentionally left blank ...
Page 262: ...2H0 2HZ 2 1 20 This page is intentionally left blank ...
Page 323: ...INSTALLATION GUIDE FOR PAPER FEEDER ...
Page 324: ...CAUTION 注 意 2007 6 303K656810 注 意 PRECAUCION VORSICHT ATTENZIONE ATTENTION ...
Page 347: ...INSTALLATION GUIDE FOR BUILT IN FINISHER ...
Page 359: ...INSTALLATION GUIDE FOR JOB SEPARATOR ...
Page 369: ...INSTALLATION GUIDE FOR FAX System M ...
Page 385: ...INSTALLATION GUIDE FOR Data Security Kit C ...
Page 388: ...INSTALLATION GUIDE FOR UG 30 ...
Page 391: ......
Page 392: ......