2H0/2HZ-1
1-5-60
4. Remove four screws and remove the HDD
mount.
5. Replace the hard disk and Install the hard
disk.
6. Refit all the removed parts.
7. When the hard disk is replaced, perform
maintenance mode U024 to initialize the
hard disk (see page 1-3-17).
When the fax backup kit is installed, perform the
following procedures (see page 1-3-79 ).
1. Run maintenance item U933 and press
[FAX IMAGE] to print out the FAX image.
2. Run maintenance item U933 and press
[JOB ACCOUNTING] to restore the job
accounting data to the hard disk.
3. Run maintenance item U933 and press
[INITIALIZE CF] to initialize the fax backup
kit.
Figure 1-5-108
Screw
Screw
Screw
Screw
HDD mount
Hard disk
Summary of Contents for KM-2560
Page 1: ...SERVICE MANUAL Published in April 2008 842H0112 2H0SM062 Rev 2 KM 2560 KM 3060 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 14: ...2H0 2HZ This page is intentionally left blank ...
Page 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank ...
Page 36: ...2H0 2HZ 2 1 2 16 This page is intentionally left blank ...
Page 262: ...2H0 2HZ 2 1 20 This page is intentionally left blank ...
Page 323: ...INSTALLATION GUIDE FOR PAPER FEEDER ...
Page 324: ...CAUTION 注 意 2007 6 303K656810 注 意 PRECAUCION VORSICHT ATTENZIONE ATTENTION ...
Page 347: ...INSTALLATION GUIDE FOR BUILT IN FINISHER ...
Page 359: ...INSTALLATION GUIDE FOR JOB SEPARATOR ...
Page 369: ...INSTALLATION GUIDE FOR FAX System M ...
Page 385: ...INSTALLATION GUIDE FOR Data Security Kit C ...
Page 388: ...INSTALLATION GUIDE FOR UG 30 ...
Page 391: ......
Page 392: ......