5-1
8
PAT-T 4kW
External contact connection.
Pins 13 and 14 of the J1 connector are used.
The release voltage across pins 13 and 14 is approx. 5 V maximum, and the short
circuit current is approx. 500
μ
A maximum. (The internal circuit is pulled up to 5 V
through 10 k
Ω
.)
Use parts with a contact rating of 5 Vdc and 0.5 mA for the external contact.
If multiple units are used under floating conditions and a single external contact is
used to turn on/off the output, isolate the signal to each unit such as by using a relay
on the external contact signal.
Fig.5-11 On/Off control connection
u
sing an external contact
■
For long-distance wiring
When wiring over a great distance, use a small relay and extend the coil side of the
relay.
Fig.5-12 On/Off control
u
sing an external contact (for long-
distance
w
iring)
Output terminal
Output terminal
Sensing terminal
+S
-S
PAT
J1
S
Two-core shielded or
twisted-pair wire
25
26
13
14
1
2
J1
13
14
Two-core shielded or
twisted-pair wire
S
Rela
Extend this
line