4-1
8
PAT-T 4kW
CF12 Preset recall setting while locked
Sets whether preset memory values can be recalled even when the lock function is
enabled.
CF13 Communication error display setting
Sets whether to display communication errors by performing a device trace.
Displays the error number when the PAT is in remote mode, and there is at least one
error in the SCPI error queue. The setting is possible even when the product is used
as a slave unit.
Fig.4-19 Error display example (Err-100 example)
CF20 CV control source setting
Selects the constant voltage control mode. Cannot be set when the output is on.
CF21 CC control source setting
Select the constant current control mode. Cannot be set when the output is on.
See
Settings
Description
0
Able to recall preset memory val
u
es in the locked condition
1
Unable to recall preset memory val
u
es in the locked condition (factory
defa
u
lt)
See
Settings
Description
oFF
N
ot display comm
u
nication errors (factory defa
u
lt)
on
Display comm
u
nication errors
EXT
EXT
RMT
LOCK
PRESET
A
B
C
A
V
OUTPUT
ALARM
See
Settings
Description
0
Panel control (factory defa
u
lt)
1
External voltage control
2
External resistance control 10 k
Ω
→
MAX OUT
3
External resistance control 10 k
Ω
→
0 OUT (FAIL SAFE)
See
Settings
Description
0
Panel control (factory defa
u
lt)
1
External voltage control
2
External resistance control 10 k
Ω
→
MAX OUT
3
External resistance control 10 k
Ω
→
0 OUT (FAIL SAFE)
Summary of Contents for PAT160-25T
Page 17: ...General Description This chapter describes an overview and describes the features...
Page 22: ...1 6 PAT T 4kW...
Page 34: ...2 12 PAT T 4kW...
Page 106: ...6 12 PAT T 4kW...
Page 158: ...7 52 PAT T 4KW...
Page 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Page 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...