PAT-T 4kW
6-9
6
P
a
rall
el/S
erie
s Opera
ti
o
n
Remote sensing
Cannot be used.
External control
Can be used.
External monitoring
•
When monitoring the output voltage or current during series
operation, the common electric potential of the monitor signal of
unit 1 and unit 2 is different.
•
External monitoring of output voltage (V MON)
The output voltage of each unit can be monitored.
•
External monitoring of output current (I MON)
The output current of each unit can be monitored.
•
Status monitors
Constant voltage operation (CV STATUS), constant current operation (CC
STATUS), output on status, POWER switch on status, and so on can be
monitored on each unit.
Alarm
All of the alarms that are detected on a single unit are also detected during series
operation.
■
Releasing the alarm
If the breaker trips, turn the power switch on after eliminating the cause of the
alarm. If the output is turned off, turn the power switch off of the unit 1 and the unit
2 in this order, after eliminating the cause of the alarm, turn the power switch on of
the unit 1 and the unit 2 in this order.
See
See
WARNING
See