7-34
PAT-T 4KW
TRIG:SOUR
Sets the condition (trigger source) for actually changing the setting after the
sequence 1 group receives INIT:SEQ1 / INIT:NAME TRAN.
Command
TRIGger[:SEQuence[1]]:SOURce {IMMediate|BUS}
TRIGger[:SEQuence[1]]:SOURce?
TRIGger[:TRANsient]:SOURce {IMMediate|BUS}
TRIGger[:TRANsient]:SOURce?
Parameter
Val
u
e:
IMM
Starts the setting immediately
BUS
Wait for a software trigger (*TRG, TRIG, or
IEEE488.1 get (Group Execute Trigger)) to change the
setting
(Default)
For the setting that is applied when *RST is sent, see Table A-16.
Response
Returns the trigger source of the sequence 1 group as character data in response to
TRIG:SOUR?.
TRIG
Executes a software trigger to the sequence 1 group.
Command
TRIGger[:SEQuence1:IMMediate]
TRIGger[:TRANsient:IMMediate]
INIT / INIT:NAME TRAN
Starts the trigger function of the sequence 1 group.
If TRIG:SOUR is set to IMM, the change starts immediately. If set to BUS, the
change starts after waiting for a software trigger.
Command
INITiate[:IMMediate][:SEQuence[1]]
INITiate[:IMMediate]:NAME TRANsition