7-36
PAT-T 4KW
TRIG:SEQ2:DEL:OFF / TRIG:OUTP:DEL:OFF
Sets the delay for turning off the output.
Command
TRIGger:SEQuence2:DELay:OFF {<numeric>|MIN|MAX}
TRIGger:SEQuence2:DELay:OFF?
TRIGger:OUTPut:DELay:OFF {<numeric>|MIN|MAX}
TRIGger:OUTPut:DELay:OFF?
Parameter
Val
u
e:
0.0 to 10.0 0 is no delay (The default value is 0.0)
Unit
S
For the setting that is applied when *RST is sent, see Table A-16.
Response
Returns the delay time until the output is turned off in the NR3 form in response to
TRIG:SEQ2:DEL:OFF? / TRIG:OUTP:DEL:OFF?.
TRIG:SEQ2:SOUR / TRIG:OUTP:SOUR
Sets the condition (trigger source) for actually starting the delay action after the
sequence 2 group receives INIT:SEQ2 / INIT:NAME OUTP.
The output turns on or off after the delay elapses.
Command
TRIGger:SEQuence2:SOURce {IMMediate|BUS}
TRIGger:OUTPut:SOURce {IMMediate|BUS}
TRIGger:SEQuence2:SOURce?
TRIGger:OUTPut:SOURce?
Parameter
Val
u
e:
IMM
Start the delay action immediately
BUS
Wait for a software trigger (*TRG, TRIG, or
IEEE488.1 get (Group Execute Trigger)) to start the
delay action
For the setting that is applied when *RST is sent, see Table A-16.
Response
Queries the trigger source setting for the sequence 2 group as character data in
response to TRIG:SEQ2:SOUR? / TRIG:OUTP:SOUR?.
Summary of Contents for PAT160-25T
Page 17: ...General Description This chapter describes an overview and describes the features...
Page 22: ...1 6 PAT T 4kW...
Page 34: ...2 12 PAT T 4kW...
Page 106: ...6 12 PAT T 4kW...
Page 158: ...7 52 PAT T 4KW...
Page 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Page 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...