To establish a LAN connection
Automatic
Configuration
1
Press
[Utility] > I/O
.
2
Press the
LAN Settings
softkey.
3
Press the
Config
softkey; then, turn the Entry knob to select
Automatic
, and press
the softkey again to enable it.
If your network supports DHCP or AutoIP, enabling
Automatic
lets the
oscilloscope use those services to get its LAN configuration settings
4
You can enable the
Multicast DNS
option to let the oscilloscope use Multicast
DNS for name resolution on small networks without a conventional DNS server.
5
Connect the oscilloscope to the local area network (LAN) by inserting the LAN
cable into the "LAN" port on the rear panel of the oscilloscope.
In a few moments the oscilloscope will connect to the network automatically.
If the oscilloscope does not automatically connect to the network, press
[Utility]
> I/O > LAN Reset
. In a few moments the oscilloscope will connect to the
network.
Manual
Configuration
1
Get the oscilloscope's network parameters (host name, IP address, subnet
mask, gateway IP, DNS IP, etc.) from your network administrator.
2
Press
[Utility] > I/O
.
3
Press the
LAN Settings
softkey.
4
Press the
Config
softkey; then, turn the Entry knob to select
Automatic
, and press
the softkey again to disable it.
If Automatic is not enabled, the oscilloscope's LAN configuration must be set
up manually using the
Addresses
and
Host name
softkeys
5
Configure the oscilloscope's LAN interface:
a
Press the
Addresses
softkey.
b
Use the
Modify
softkey (and the other softkeys and the Entry knob) to enter
the IP Address, Subnet Mask, Gateway IP, and DNS IP values. When you are
done, go back up in the menu hierarchy.
c
Press the
Host name
softkey. Use the softkeys and the Entry knob to enter the
Host name. When you are done, go back up in the menu hierarchy.
d
Press the
Apply
softkey.
6
Connect the oscilloscope to the local area network (LAN) by inserting the LAN
cable into the "LAN" port on the rear panel of the oscilloscope.