Waveform Generator
19
Keysight InfiniiVision 1200 X-Series and EDUX1052A/G Oscilloscopes User's Guide
209
4
In the Wave Gen Mod menu:
•
Press the
Modulation
softkey to enable or disable
modulated waveform generator output.
You can enable modulation for all waveform generator
function types except pulse, DC, and noise.
•
Press the
Type
softkey and turn the Entry knob to select
the modulation type:
•
Amplitude Modulation (AM)
— the amplitude of the
original carrier signal is modified according to the
amplitude of the modulating signal. See
•
Frequency Modulation (FM)
— the frequency of the original
carrier signal is modified according to the amplitude of
the modulating signal. See
•
Frequency-Shift Keying Modulation (FSK)
— the output
frequency "shifts" between the original carrier frequency and a "hop
frequency" at the specified FSK rate. The FSK rate specifies a digital
square wave modulating signal. See
"To set up Frequency-Shift Keying
To set up Amplitude Modulation (AM)
In the Wave Gen Mod menu (under
[Wave Gen] > Settings > Modulation
):
1
Press the
Type
softkey and turn the Entry knob to select
Amplitude Modulation
(AM)
.
2
Press the
Waveform
softkey and turn the Entry knob to select the shape of the
modulating signal:
•
Sine
•
Square
•
Ramp
When the
Ramp
shape is selected, a
Symmetry
softkey appears so that you can
specify the amount of time per cycle that the ramp waveform is rising.
3
Press the
AM Freq
softkey and turn the Entry knob to specify the frequency of
the modulating signal.