Waveform Generator
19
Keysight InfiniiVision 1200 X-Series and EDUX1052A/G Oscilloscopes User's Guide
207
•
High-Z
The output impedance of the Gen Out BNC is fixed at 50 ohms. However, the
output load selection lets the waveform generator display the correct amplitude
and offset levels for the expected output load.
If the actual load impedance is different than the selected value, the displayed
amplitude and offset levels will be incorrect.
To use waveform generator logic presets
With logic level presets, you can easily set the output voltage to TTL, CMOS
(5.0V), CMOS (3.3V), CMOS (2.5V), or ECL compatible Low and High levels.
1
If the Wave Gen menu is not currently displayed on the oscilloscope's softkeys,
press the
[Wave Gen]
key.
2
In the Wave Gen menu, press the
Settings
softkey.
3
In the Wave Gen Settings menu, press the
Logic Presets
softkey.
4
In the Wave Gen Presets menu, press one of the softkeys to set the generated
signal's Low and High voltages to logic compatible levels:
To add noise to the waveform generator output
1
If the Wave Gen menu is not currently displayed on the oscilloscope's softkeys,
press the
[Wave Gen]
key.
Softkey (logic levels)
Low level
High level, 50 ohm
expected output load
High level, high-Z
expected output load
TTL
0 V
+2.5 V (TTL compatible)
+5 V
CMOS (5.0V)
0 V
Not Available
+5 V
CMOS (3.3V)
0 V
+2.5 V (CMOS
compatible)
+3.3 V
CMOS (2.5V)
0 V
+2.5 V
+2.5 V
ECL
-1.7 V
-0.8 V (ECL compatible)
-0.9 V