126
Programming
Lists of Commands
:DISPlay:MARKer:MAXimum:NEXT
Moves the marker to the signal with the closest power
level just below the power level of the signal at the current
marker position.
I
:DISPlay:MARKer:MAXimum:PREVious
Moves the marker to the signal with the closest power
level just above the power level of the signal at the current
marker position.
I
:DISPlay:MARKer:MAXimum:RIGHt
Moves marker to the next higher wavelength or
frequency.
I
:DISPlay[:WINDow]:GRAPhics:STATe
Turns the instrument display of the power bars on and off.
S
HCOPy Subsystem
:HCOPy:IMMediate
Starts a printout.
S
SENSe Subsystem
:SENSe:CORRection:DEVice
Configures wavelength measurements for narrowband or
broadband devices.
I
:SENSe:CORRection:ELEVation
Sets the elevation value used by the instrument to
compensate for air dispersion.
I
:SENSe:CORRection:OFFSet:MAGNitude
Sets the power offset value used by the instrument.
S
:SENSe:CORRection:MEDium
Sets the instrument to return the wavelength reading in a
vacuum when the parameter is on. Parameters are VAC
and AIR.
I
:SENSe:DATA?
Queries the time domain samples of the input signal.
I
STATus Subsystem
:STATus:{OPERation | QUEStionable}:CON
Dition?
Returns the value for the condition register for the node.
S
:STATus:{OPERation | QUEStionable}:EVE
Nt?
Returns the value of the event register for the node.
S
:STATus:{OPERation | QUEStionable}:ENA
Ble
Sets the enable register.
S
:STATus:{OPERation | QUEStionable}:PTR
ansition
Sets the positive transition filter register.
S
:STATus:{OPERation | QUEStionable}:NTR
ansition
Sets the negative transition filter register.
S
:STATus:PRESet
Presets the enable registers for all status nodes.
S
SYSTem Subsystem
:SYSTem:ERRor?
Queries an error from the error queue.
S
Table 4-11. Programming Commands (4 of 5)
Command
Description
Code
Codes: S indicates a standard SCPI command. I indicates an instrument specific command.
Summary of Contents for 86120B
Page 1: ...Keysight 86120B Multi Wavelength Meter User s Guide...
Page 2: ......
Page 3: ...1...
Page 12: ...10 General Safety Considerations...
Page 68: ...You can use the ABORT and CONT softkey to stop and restart a print job that is in progress...
Page 100: ...98 Programming Monitoring the Instrument...
Page 231: ...229 Performance Tests Test 5 Amplitude Accuracy and Linearity...
Page 232: ......
Page 244: ...242 Specifications and Regulatory Information Product Overview...
Page 250: ...248 Reference Menu Maps Display List by Power Menu Display List by WL Menu...
Page 251: ...249 Reference Menu Maps Delta On Menu Delta Off Menu...
Page 253: ...251 Reference Menu Maps System Print Menu...
Page 254: ...252 Reference Menu Maps System Setup Menu...
Page 272: ......