124
Programming
Lists of Commands
CALCulate1 Subsystem
:CALCulate1:DATA?
Queries the uncorrected frequency-spectrum data of the
input signal.
S
:CALCulate1:TRANsform:FREQuency:POI
Nts?
Sets and queries the number of points in the data set.
S
CALCulate2 Subsystem
:CALCulate2:DATA?
Queries the corrected frequency-spectrum data of the
input signal.
S
:CALCulate2:PEXCursion
Sets the peak excursion limit.
I
:CALCulate2:POINts?
Queries the number of points in the data set.
I
:CALCulate2:PTHReshold
Sets the peak threshold limit.
I
:CALCulate2:PWAVerage[:STATe]?
Places the instrument in the average-wavelength mode.
Data queries return the power-weighted average
frequency, wavelength, or wavenumber or total power.
I
:CALCulate2:WLIMit[:STATe]
Limits input wavelength range of the Keysight 86120B.
I
:CALCulate2:WLIMit:STARt:FREQuency
Sets the starting frequency for the wavelength limit range.
I
CALCulate2:WLIMit:STARt[:WAVelength]
Sets the starting wavelength for the wavelength limit
range.
I
CALCulate2:WLIMit:STARt:WNUMber
Sets the starting wavenumber for the wavelength limit
range.
I
:CALCulate2:WLIMit:STOP:FREQuency
Sets the stopping frequency for the wavelength limit
range.
I
CALCulate2:WLIMit:STOP[:WAVelength]
Sets the stopping wavelength for the wavelength limit
range.
I
CALCulate2:WLIMit:STOP:WNUMber
Sets the stopping wavenumber for the wavelength limit
range.
I
CALCulate3 Subsystem
CALCulate3:ASNR:CLEar
Resets and restarts the signal-to-noise ratio averaging
I
CALCulate3:ASNR:COUNt
Sets the number of measurements to average the signal-
to-noise ratio
I
CALCulate3:ASNR:[:STATe]
Turns signal-to-noise ratio averaging mode on and off
I
:CALCulate3:DATA?
Queries the data resulting from delta, drift, and signal-to-
noise measurements.
S
:CALCulate3:DELTa:POWer[:STATe]
Turns the delta power measurement mode on and off.
I
:CALCulate3:DELTa:REFerence:FREQuenc
y
Selects the signal to be used as the reference for the
DELTa calculations.
I
Table 4-11. Programming Commands (2 of 5)
Command
Description
Code
Codes: S indicates a standard SCPI command. I indicates an instrument specific command.
Summary of Contents for 86120B
Page 1: ...Keysight 86120B Multi Wavelength Meter User s Guide...
Page 2: ......
Page 3: ...1...
Page 12: ...10 General Safety Considerations...
Page 68: ...You can use the ABORT and CONT softkey to stop and restart a print job that is in progress...
Page 100: ...98 Programming Monitoring the Instrument...
Page 231: ...229 Performance Tests Test 5 Amplitude Accuracy and Linearity...
Page 232: ......
Page 244: ...242 Specifications and Regulatory Information Product Overview...
Page 250: ...248 Reference Menu Maps Display List by Power Menu Display List by WL Menu...
Page 251: ...249 Reference Menu Maps Delta On Menu Delta Off Menu...
Page 253: ...251 Reference Menu Maps System Print Menu...
Page 254: ...252 Reference Menu Maps System Setup Menu...
Page 272: ......