![Kärcher SB MU Manual Download Page 71](http://html1.mh-extra.com/html/karcher/sb-mu/sb-mu_manual_655662071.webp)
-
33
Interruptions in water preparation
Fault
Possible cause
Remedy
By whom
Base exchanger
is not regenerat-
ing
No power supply
Check power supply (fuse, plug, switch).
Operator/
Customer
Service
Hardness sensor defective
Check hardness sensor, replace if required
Customer
Service
Water remains
hard after regen-
eration
No salt in the salt tank
Fill up salt, do not allow the salt level to fall below
the water level.
Operator
Injector filter is blocked
Clean the filter
Customer
Service
Water flow to the salt tank is inadequate
Check the brine filling duration; clean the brine fill-
ing aperture, if required.
Customer
Service
Rising pipe is leaky
Check rising pipe, pilot pipe
Customer
Service
too high salt con-
sumption
too much water in the water tank
see below
Customer
Service
wrong salt quantity setting
Check salt consumption and salt settings
Customer
Service
Pressure loss
Deposits in water inlet
Clean the filter
Customer
Service
Deposits in base exchanger
Clean valve and resin board
Customer
Service
Too much water
in the salt tank
Rinsing aperture is blocked
Clean rinsing aperture
Customer
Service
Injector is blocked
Clean injector and filter
Customer
Service
Foreign particles in the solenoid valve
Clean the solenoid valve, change the valve seat
Customer
Service
Power failure while filling brine
Check power source
Customer
Service
Brine is not get-
ting sucked in
Water inlet pressure is too low
Increase water pressure to at least 0.3 MPa (3
bar).
Operator
Rinsing aperture is blocked
Clean rinsing aperture
Customer
Service
Injector is blocked
Clean injector and filter
Customer
Service
Leak inside the valve
Replace valve flaps
Customer
Service
There is always
water in the
drainage, even
after regenera-
tion
Valve does not execute the correct cycles
Check timer programme; replace the valve con-
trols, if required
Customer
Service
Foreign particle in the valve
Remove the valve control, take out the foreign
particle, check valve in all the positions
Customer
Service
71
EN
Summary of Contents for SB MU
Page 2: ...2 ...
Page 9: ... 7 1 Menuepunkt 2 Parameter 9 DE ...
Page 15: ... 13 Funktion Fließschema 2 Werkzeug Ausführung 15 DE ...
Page 16: ... 14 Fließschema 1 Werkzeug Ausführung 16 DE ...
Page 21: ... 19 21 DE ...
Page 45: ... 7 1 Menu item 2 Parameter 45 EN ...
Page 51: ... 13 Function Flow chart 2 tool design 51 EN ...
Page 52: ... 14 Flow chart 1 tool design 52 EN ...
Page 57: ... 19 57 EN ...
Page 82: ... 7 1 Rubrique de menu 2 Paramètre 82 FR ...
Page 88: ... 13 Fonction Schéma de flux exécution à 2 outils 88 FR ...
Page 89: ... 14 Schéma de flux exécution à 1 outils 89 FR ...
Page 94: ... 19 94 FR ...
Page 119: ... 7 1 Punto del menú 2 Parámetros 119 ES ...
Page 125: ... 13 Función Esquema de flujo modelo con 2 herramientas 125 ES ...
Page 126: ... 14 Esquema de flujo modelo con 1 herramienta 126 ES ...
Page 131: ... 19 131 ES ...
Page 159: ... 7 1 Menypunkt 2 Parameter 159 SV ...
Page 160: ... 8 1 Menypunkt 2 Parameter 160 SV ...
Page 167: ... 15 Funktion Flödesschema 2 verktygs utförande 167 SV ...
Page 168: ... 16 Flödesschema 1 verktygs utförande 168 SV ...
Page 173: ... 21 173 SV ...
Page 174: ... 22 174 SV ...
Page 194: ......