29
During normal operation, active faults are
shown alternating in sequence.
The number in parentheses shows the total
number of faults present.
If a fault must be acknowledged, the dis-
play will stand still:
Fault code (F: XXX) locate the fault in
the table above and follow the instruc-
tions to eliminate the fault.
To acknowledge, press the „ESC“ key.
Press the "OK" button to confirm.
The fault is acknowledged.
Note
If more faults should be displayed without
confirming the displayed fault, press the
key RIGHT.
The control can store a maximum of 256
occurred faults.
When the fault list is full, the oldest mes-
sage will be overwritten by the newest one.
Press the "ESC" key repeatedly until
the following display appears:
Press OK button for more than 2 sec-
onds.
Press the LEFT button.
Sum of archived fault messages
Press "OK" in order to get into the most
recently archived fault message.
1 Date of fault occurrence
2 Time of fault occurrence
3 Errow code
4 List position/number of same faults in
the fault list
Browse through the fault list using the
"LEFT" and "RIGHT" keys.
Details of the currently displayed fault
can be viewed via the "OK" key.
1 Error description
2 Errow code
3 Number of same faults in the fault list
Press the keys LEFT and RIGHT simul-
taneously.
Press "OK" in order to delete the fault
list
or
Press "ESC" in order not to delete the
fault list
F 284
Contactor of pump for rim cleaner is jammed
Call customer service.
F 300
No connection to electronics A7
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 301
Outputs of the electronics A7 overloaded
F 320
No connection to electronics A8
F 321
Outputs of the electronics A8 overloaded
F 322
Current consumption of pump for micro-emulsion (intensive cleaning
complete) too high
F 323
Current consumption of pump for micro-emulsion (intensive cleaning
complete) too low
F 324
Contactor of pump for micro-emulsion (intensive cleaning complete)
is jammed
Call customer service.
F 400
Warm water no pressure
Check water supply.
F 401
Fresh water no pressure
F 402
Permeate no pressure
F 403
Service water no pressure
F 420
Fault token changer 1
Check token changer.
F 421
Fault token changer 2
Display
Cause
Remedy
Acknowledge the faults
Viewing the list of faults
Clearing the error memory
67
EN
Summary of Contents for SB MU
Page 2: ...2 ...
Page 9: ... 7 1 Menuepunkt 2 Parameter 9 DE ...
Page 15: ... 13 Funktion Fließschema 2 Werkzeug Ausführung 15 DE ...
Page 16: ... 14 Fließschema 1 Werkzeug Ausführung 16 DE ...
Page 21: ... 19 21 DE ...
Page 45: ... 7 1 Menu item 2 Parameter 45 EN ...
Page 51: ... 13 Function Flow chart 2 tool design 51 EN ...
Page 52: ... 14 Flow chart 1 tool design 52 EN ...
Page 57: ... 19 57 EN ...
Page 82: ... 7 1 Rubrique de menu 2 Paramètre 82 FR ...
Page 88: ... 13 Fonction Schéma de flux exécution à 2 outils 88 FR ...
Page 89: ... 14 Schéma de flux exécution à 1 outils 89 FR ...
Page 94: ... 19 94 FR ...
Page 119: ... 7 1 Punto del menú 2 Parámetros 119 ES ...
Page 125: ... 13 Función Esquema de flujo modelo con 2 herramientas 125 ES ...
Page 126: ... 14 Esquema de flujo modelo con 1 herramienta 126 ES ...
Page 131: ... 19 131 ES ...
Page 159: ... 7 1 Menypunkt 2 Parameter 159 SV ...
Page 160: ... 8 1 Menypunkt 2 Parameter 160 SV ...
Page 167: ... 15 Funktion Flödesschema 2 verktygs utförande 167 SV ...
Page 168: ... 16 Flödesschema 1 verktygs utförande 168 SV ...
Page 173: ... 21 173 SV ...
Page 174: ... 22 174 SV ...
Page 194: ......
Page 195: ......