26
F 036
Coiling protection contact of high pressure pump washing station 2
has triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 037
Oil level of high pressure pump at washing station 2 too low
Refill oil, acknowledge the fault.
F 038
Electronics at washing station 2 defective
Call customer service.
F 040
No connection to remote control electronics at washing station 2
Check the connector of the data cable with the
electronics of the remote control.
F 041
Fault at coin acceptor at washing station 2
Call customer service.
F 042
Check the microswitch on the mechanical coin
acceptor, replace electronic coin acceptor
F 050
No connection to pump electronics at washing station 3
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 051
Electronic outlets at washing station 3 overloaded
F 052
Current pickup of high pressure pump at washing station 3 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 053
Current pickup of high pressure pump at washing station 3 too low
See "Faults on high pressure pumps"
F 054
Contact of high pressure pump at washing station 3 stuck
Call customer service.
F 055
Semiload valve at washing station 3 defective
F 056
Coiling protection contact of high pressure pump washing station 3
has triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 057
Oil level of high pressure pump at washing station 3 too low
Refill oil, acknowledge the fault.
F 058
Electronics at washing station 3 defective
Call customer service.
F 060
No connection to remote control electronics at washing station 3
Check the connector of the data cable with the
electronics of the remote control.
F 061
Fault at coin acceptor at washing station 3
Call customer service.
F 062
Check the microswitch on the mechanical coin
acceptor, replace electronic coin acceptor
F 070
No connection to pump electronics at washing station 4
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 071
Electronic outlets at washing station 4 overloaded
F 072
Current pickup of high pressure pump at washing station 4 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 073
Current pickup of high pressure pump at washing station 4 too low
See "Faults on high pressure pumps"
F 074
Contact of high pressure pump at washing station 4 stuck
Call customer service.
F 075
Semiload valve at washing station 4 defective
F 076
Coiling protection contact of high pressure pump washing station 4
has triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 077
Oil level of high pressure pump at washing station 4 too low
Refill oil, acknowledge the fault.
F 078
Electronics at washing station 4 defective
Call customer service.
F 080
No connection to remote control electronics at washing station 4
Check the connector of the data cable with the
electronics of the remote control.
F 081
Fault at coin acceptor at washing station 4
Call customer service.
F 082
Check the microswitch on the mechanical coin
acceptor, replace electronic coin acceptor
F 090
No connection to pump electronics at washing station 5
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 091
Electronics outlets at washing station 5 overloaded
F 092
Current consumption of high-pressure pump at washing station 5 too
high
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 093
Current consumption of high-pressure pump at washing station 5 too
low
See "Faults on high pressure pumps"
F 094
Contactor of high-pressure pump at washing station 5 jammed
Call customer service.
F 095
Semiload valve at washing station 5 defective
Display
Cause
Remedy
64
EN
Summary of Contents for SB MU
Page 2: ...2 ...
Page 9: ... 7 1 Menuepunkt 2 Parameter 9 DE ...
Page 15: ... 13 Funktion Fließschema 2 Werkzeug Ausführung 15 DE ...
Page 16: ... 14 Fließschema 1 Werkzeug Ausführung 16 DE ...
Page 21: ... 19 21 DE ...
Page 45: ... 7 1 Menu item 2 Parameter 45 EN ...
Page 51: ... 13 Function Flow chart 2 tool design 51 EN ...
Page 52: ... 14 Flow chart 1 tool design 52 EN ...
Page 57: ... 19 57 EN ...
Page 82: ... 7 1 Rubrique de menu 2 Paramètre 82 FR ...
Page 88: ... 13 Fonction Schéma de flux exécution à 2 outils 88 FR ...
Page 89: ... 14 Schéma de flux exécution à 1 outils 89 FR ...
Page 94: ... 19 94 FR ...
Page 119: ... 7 1 Punto del menú 2 Parámetros 119 ES ...
Page 125: ... 13 Función Esquema de flujo modelo con 2 herramientas 125 ES ...
Page 126: ... 14 Esquema de flujo modelo con 1 herramienta 126 ES ...
Page 131: ... 19 131 ES ...
Page 159: ... 7 1 Menypunkt 2 Parameter 159 SV ...
Page 160: ... 8 1 Menypunkt 2 Parameter 160 SV ...
Page 167: ... 15 Funktion Flödesschema 2 verktygs utförande 167 SV ...
Page 168: ... 16 Flödesschema 1 verktygs utförande 168 SV ...
Page 173: ... 21 173 SV ...
Page 174: ... 22 174 SV ...
Page 194: ......
Page 195: ......