6
1 Battery pole fuse
Î
Connect the connection cable to the
free battery poles (+) and (-).
Î
Tilt the water tank towards the front.
Î
Insert the screw for fastening the tank
and tighten it.
Caution
Charge the batteries before commissioning
the machine.
Danger
Danger of explosion. Wet batteries can
only be charged with opened hood.
Note
The device is equipped with a safety mech-
anism to prevent total discharge, i.e. when
the permissible minimum capacity is
reached, then the brush motors and the tur-
bine are switched off. In such a case, the
battery level indicator on the control con-
sole glows red.
In ...W Bp Pack model, the traction is still
active:
Î
Drive the machine directly to the charg-
ing station; avoid any steep gradients in
the process.
Note
If the safety mechanism to prevent total dis-
charge has got activated, then the battery
must first be charged fully (until the battery
level indicator glows green). Only then will
the electronic system unlock the functions.
Danger
Risk of electric shock. Observe supply net-
work and fuse protection - see "Charger".
Only use the charger in dry rooms with suf-
ficient ventilation!
Note
Average charging time is approx. 10 -15
hours.
The recommended chargers (matching the
batteries used) are regulated electronically
and will automatically switch off the charg-
ing process.
All functions of the machine are automati-
cally interrupted during the charging proc-
ess.
Î
Insert the plug of the charger into the
socket.
Note
The charger has electronic controls and au-
tomatically switches off the charging proc-
ess. All functions of the machine are
automatically interrupted during the charg-
ing process.
The battery control display shows the
progress of the charging process when the
plug is inserted:
Note
If the interruption indicator glows during the
charging process, then see details in the
chapter on trouble-shooting.
Î
Remove battery plug and join it to the
charging cable.
Î
Connect the charger to the mains and
turn it on.
Note
Connect the charger using the battery plug
of the appliance and not by removing the
cable of the electronics system.
.
Press emergency-stop button:
–
the charging process is cancelled
–
the display shows the "Notaus-
Schalter!“ oder „Emergency button“
–
the interruption display flashes
Charging battery
Charging process for Bp Pack model
Refresh and main
charging
quickly blinks yellow
Retention charging
(battery is full)
glows green
Charging process for Bp version
Emergency-stop switch during charging
process (only BR/BD...W...Bp Pack)
30
EN
Summary of Contents for BR/BD 45/40 W Bp Pack
Page 2: ...2 ...
Page 5: ... 3 Bedienelemente 5 DE ...
Page 27: ... 3 Operating elements 27 EN ...
Page 48: ... 3 Eléments de commande 48 FR ...
Page 70: ... 3 Dispositivi di comando 70 IT ...
Page 92: ... 3 Bedieningselementen 92 NL ...
Page 114: ... 3 Elementos de mando 114 ES ...
Page 136: ... 3 Elementos de manuseamento 136 PT ...
Page 158: ... 3 Betjeningselementer 158 DA ...
Page 179: ... 3 Betjeningselementer 179 NO ...
Page 200: ... 3 Reglage 200 SV ...
Page 221: ... 3 Hallintaelementit 221 FI ...
Page 242: ... 3 Στοιχεία χειρισμού 242 EL ...
Page 265: ... 3 Kumanda elemanları 265 TR ...
Page 287: ... 4 Элементы управления 287 RU ...
Page 311: ... 3 Kezelési elemek 311 HU ...
Page 333: ... 3 Ovládací prvky 333 CS ...
Page 355: ... 3 Upravljalni elementi 355 SL ...
Page 377: ... 3 Elementy obsługi 377 PL ...
Page 400: ... 3 Elemente de operare 400 RO ...
Page 422: ... 3 Ovládacie prvky 422 SK ...
Page 444: ... 3 Komandni elementi 444 HR ...
Page 490: ... 4 Обслужващи елементи 490 BG ...
Page 514: ... 3 Teeninduselemendid 514 ET ...
Page 535: ... 3 Valdymo elementai 535 LT ...
Page 557: ... 3 Vadības elementi 557 LV ...
Page 579: ... 3 Елементи пристрою 579 UK ...
Page 600: ......
Page 601: ......
Page 602: ......
Page 603: ......