INSTALLATION MANUAL
INSTALLATION OF THE FRIGOSCANDIA
FRIGOBELT
®
CONVEYOR
This document together with drawings describes a safe and
easy way to install FRIGoBELT Conveyor in a
Frigoscandia GYRoCOMPACT
®
equipment with a
FRIGoDRIVE
®
or a FRIGoDRIVE M System
Warning
Handle the conveyor belt carefully. The
conveyor belt can easily be damaged.
Warning
Be careful and alert in order to avoid getting
caught by the conveyor belt when running it.
Clothing’s, fingers and other parts of the body
can easily get caught in the conveyor belt
causing serious body injury.
Installation
1. Adjust the transfer area.
Refer to installation instruction “Transfer area control”
1000-07-01-29-##
valid for FRIGoDRIVE
1100-07-01-29-##
valid for FRIGoDRIVE M
2. Carefully pull the first piece of conveyor belt onto the infeed
rails.
3. Make final adjustments to the infeed rails.
4. Fit the Curve loader
1)
in place.
Refer to installation instruction “Curve loader”
1000-07-01-21-##.
Note!
Mounting and all adjustments of the Curve loader
1)
must be
done directly after the infeed rail geometry is adjusted. Ignoring
this recommendation will make it almost impossible to adjust
the Curve loader later on in the installation process.
5. Splice the second piece of the conveyor belt to the first and
weld the rod to the links.
Refer to Manual sheet “Adjusting the conveyor belt length”
1000-06-01-10-##
6. Install the conveyor belt, as far as possible (see point 7),
onto the drive chains, without running the drive system. Do
as follows:
•
One person, standing in front of the belt, pulls the conveyor
belt on top of the chains. At the same time make sure the
conveyor belt is pushed against the z-clip of the inner chain.
® = Registered trade mark of JBT FoodTech.
Subject to change without notice.
1)
If installed
Summary of Contents for FoodTech Frigoscandia GYRoCOMPACT M7
Page 1: ...0 INSTALLATION MANUAL Frigoscandia GYRoCOMPACT M7 Spiral Freezer...
Page 2: ...N...
Page 4: ...INSTALLATION 2 2 INTRODUCTION 02 INSTALLATION MANUAL...
Page 6: ...2 2 0000 07 01 01 00 INSTALLATION MANUAL INSTALLATION...
Page 8: ...2 2 0000 07 01 02 00 INSTALLATION MANUAL INSTALLATION...
Page 16: ...10 0000 00 01GB 11 24 SAFETY...
Page 20: ...SAFETY 4 1000 07 01GB 02 03...
Page 34: ...6 INSTALLATION PREPARATIONS 1000 07 01GB 05 03...
Page 42: ...8 DELIVERY INFORMATION 0000 03 01GB 11 09...
Page 44: ...2 INSTALLATION 1000 07 01GB 07 01 INSTALLATION MANUAL...
Page 48: ...2 INSTALLATION 1000 07 01GB 09 03 INSTALLATION MANUAL...
Page 54: ...2 INSTALLATION 1000 07 01GB 12 00 INSTALLATION MANUAL...
Page 58: ...4 INSTALLATION 1000 07 01GB 13 01 INSTALLATION MANUAL...
Page 62: ...2 INSTALLATION 1000 07 01GB 15 00 INSTALLATION MANUAL...
Page 70: ...2 INSTALLATION INSTALLATION MANUAL 1000 07 01GB 18 01...
Page 72: ...2 INSTALLATION 1000 07 01GB 20 00 INSTALLATION MANUAL...
Page 78: ...6 INSTALLATION 1000 07 01GB 22 03 INSTALLATION MANUAL...
Page 90: ...4 INSTALLATION 1000 07 01GB 29 00 INSTALLATION MANUAL...
Page 110: ...6 INSTALLATION 1000 07 01GB 25 01 INSTALLATION MANUAL...
Page 128: ...18 INSTALLATION 1000 07 01GB 26 06...
Page 144: ...2 INSTALLATION 1000 07 01GB 19 00 INSTALLATION MANUAL...
Page 152: ...2 INSTALLATION 1000 07 01GB 36 00 INSTALLATION MANUAL...
Page 194: ...10 221 01GB 03 SERVICE INFO...
Page 200: ...10 171 01GB 02 SERVICE INFO...
Page 222: ...172 347 01GB 00 SERVICE INFO...
Page 230: ...10 039 01GB 03 SERVICE INFORMATION...
Page 256: ...172 CORRECTIVEMAINTENANCE 1000 06 01GB 10 11...
Page 269: ...Automatic Pump Station PZC M1 PZE M2 CIP M3 Directions for use 3 19 EN...
Page 277: ...9 ALTO Danmark A S...