12
ALTO Danmark A/S
Fault
Cause
Remedy
The machine does not start
Fuse blown
Power supply fault
Fuse in the wiring box of the
machine blown.
Motor overload in the wiring box of
machine disconnected.
Check fuse and replace, if necessary
Power supply to be checked by an
expert.
Check fuse and replace, if necessary.
Before switching on again, check
cause of disconnection.
The machine does not build
up pressure.
The program does not function
correctly.
No water supply.
Direction of rotation of the pump is
not correct.
Check the program.
Please call for assistance by FRIGO-
SCANDIA, if necessary.
Open inlet valve of machine.
Change direction of rotation of pump
in accordance with arrow on pump.
Unstable or too low pump
pressure.
Insufficient water supply.
Strainer on inlet pipe blocked up.
Provide sufficient water supply. Min. 1
1/4" piping.
Clean or replace filter.
Unsatisfactory foam quality.
Detergent not suitable.
Too low concentration of the
detergent.
Too high temperature of teh inlet
water.
Insufficient air quantity and
pressure.
Change to correct type of detergent.
Ensure sufficient detergent supply,
2-4%.
Reduce the temperature of the water.
Ensure sufficient air supply, 500
l/min., 5 bar.
Spreading of foam is not
uniform.
Insufficient air supply to the system.
Incorrect air pressure on the
system.
Too high air pressure in the injector
(read pressure on pressure gauge.
Incorrect nozzles mounted.
Ensure sufficient air supply, 500
l/min., 5 bar.
Set pressure on 5 bar on the
regu lating valve.
Set pressure on 5 bar on the
regu lating valve.
Contact FRIGOSCANDIA for instruc-
tions.
No spreading of foam.
The program does not function
correctly.
The non-return valve in the injector
is blocked up.
The dosing valve for detergetn is
blocked up.
Check the program. Call for FRIGO-
SCANDIA assistance, if necessary.
Clean or replace the valve.
Clean or replace the valve.
No pressure air in the system.
Inlet valve for pressure air is not
open.
The solenoid valve for pressure air is
blocked up or defective.
Open inlet valve for pressure air.
Clean or replace the solenoid valve.
Summary of Contents for FoodTech Frigoscandia GYRoCOMPACT M7
Page 1: ...0 INSTALLATION MANUAL Frigoscandia GYRoCOMPACT M7 Spiral Freezer...
Page 2: ...N...
Page 4: ...INSTALLATION 2 2 INTRODUCTION 02 INSTALLATION MANUAL...
Page 6: ...2 2 0000 07 01 01 00 INSTALLATION MANUAL INSTALLATION...
Page 8: ...2 2 0000 07 01 02 00 INSTALLATION MANUAL INSTALLATION...
Page 16: ...10 0000 00 01GB 11 24 SAFETY...
Page 20: ...SAFETY 4 1000 07 01GB 02 03...
Page 34: ...6 INSTALLATION PREPARATIONS 1000 07 01GB 05 03...
Page 42: ...8 DELIVERY INFORMATION 0000 03 01GB 11 09...
Page 44: ...2 INSTALLATION 1000 07 01GB 07 01 INSTALLATION MANUAL...
Page 48: ...2 INSTALLATION 1000 07 01GB 09 03 INSTALLATION MANUAL...
Page 54: ...2 INSTALLATION 1000 07 01GB 12 00 INSTALLATION MANUAL...
Page 58: ...4 INSTALLATION 1000 07 01GB 13 01 INSTALLATION MANUAL...
Page 62: ...2 INSTALLATION 1000 07 01GB 15 00 INSTALLATION MANUAL...
Page 70: ...2 INSTALLATION INSTALLATION MANUAL 1000 07 01GB 18 01...
Page 72: ...2 INSTALLATION 1000 07 01GB 20 00 INSTALLATION MANUAL...
Page 78: ...6 INSTALLATION 1000 07 01GB 22 03 INSTALLATION MANUAL...
Page 90: ...4 INSTALLATION 1000 07 01GB 29 00 INSTALLATION MANUAL...
Page 110: ...6 INSTALLATION 1000 07 01GB 25 01 INSTALLATION MANUAL...
Page 128: ...18 INSTALLATION 1000 07 01GB 26 06...
Page 144: ...2 INSTALLATION 1000 07 01GB 19 00 INSTALLATION MANUAL...
Page 152: ...2 INSTALLATION 1000 07 01GB 36 00 INSTALLATION MANUAL...
Page 194: ...10 221 01GB 03 SERVICE INFO...
Page 200: ...10 171 01GB 02 SERVICE INFO...
Page 222: ...172 347 01GB 00 SERVICE INFO...
Page 230: ...10 039 01GB 03 SERVICE INFORMATION...
Page 256: ...172 CORRECTIVEMAINTENANCE 1000 06 01GB 10 11...
Page 269: ...Automatic Pump Station PZC M1 PZE M2 CIP M3 Directions for use 3 19 EN...
Page 277: ...9 ALTO Danmark A S...