REL0.2
Page 82 of 88
Zynq Ult MPSoC SBC Hardware User Guide
iWave Systems Technologies Pvt. Ltd.
3.3
Environmental Characteristics
3.3.1
Temperature Specification
The below table provides the Environment specification of Zynq Ult MPSoC SBC.
Table 18: Temperature Specification
Parameters
Min
Max
Operating temperature range - Industrial
1
-40°C
85°C
Operating temperature range - Extended
1
0°C
85°C
¹ iWave guarantees the component selection for the given operating temperature. The operating temperature at the
system level will be affected by the various system components like carrier board and its components, system enclosure,
air circulation in the system, system power supply etc. Based on the system design, specific heat dissipating approach
might be required from system to system. It is recommended to do the necessary system level thermal simulation and
find necessary thermal solution in the system before using this board in the end application.
3.3.2
RoHS2 Compliance
iWave’s
Zynq Ult MPSoC SBC is designed by using RoHS2 compliant components and manufactured on lead
free production process.
3.3.3
Electrostatic Discharge
iWave’s
Zynq Ult MPSoC SBC is sensitive to electro static discharge and so high voltages caused by static
electricity could damage some of the devices on board. It is packed with necessary protection while shipping. Do not
open or use the SBC except at an electrostatic free workstation.
3.3.4
Heat Sink
For any highly integrated SBC
, thermal design is very important factor. As IC’s size is decreasing and performance of
module is increasing by rising processor frequencies, it generates high amount of heat which should be dissipated for
the system to work as expected without fault.
To dissipate the heat, appropriate thermal management technique Heat sink must be used. Always remember that, if
you use more effective thermal solution, you will get more performance out of the CPU.