Intel® Server System M50FCP1UR System Integration and Service Guide
83
9.
Align and insert the M.2 SSD with the connector on the server board. See Letter A.
10.
11.
Using the screw, secure the SSD to the mounting stand-off on the server board
(see Letter B). Tighten to 1.5 in-lb.
12.
Reinstall the riser card assembly (see
Section 6.6
13.
Reinstall the system top cover (see
Section 6.1.2
6.11
Intel® RAID Maintenance Free Backup Unit (RMFBU) Replacement
This section provides instructions to replace an RMFBU bracket and assembly in the system.
Required Tools and Supplies
•
Replacement RMFBU Kit
•
Anti-static wrist strap and conductive workbench pad (recommended)
Figure 115. Intel® RMFBU Mounting Bracket Removal - Chassis
1.
Remove the system top cover (see
Section 6.1.1
2.
Disconnect RMFBU cables.
3.
Locate the RMFBU housing assembly and slide the latch up to unlock the assembly from the
mounting plate (see Letter A).
4.
Slide the RMFBU housing assembly (see Letter B) towards the system fans. When free from the
mounting plate, lift it up and out of the system.
5.
Remove the RMFBU from the plastic housing
6.
Locate and carefully unpack the replacement RMFBU
Figure 116. RMFBU Housing Assembly
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Page 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...