Intel® Server System M50FCP1UR System Integration and Service Guide
37
1.
If the riser card assembly (bracket and riser card) is still inside the system, remove it from the system
following instructions in
Section 3.2.1
2.
Remove the screw (see Letter A) holding the filler plate to the bracket. Remove the filler plate. See
Letter B.
3.
Insert the add-in card until it is fully seated inside the PCIe* slot on the riser card. See Letter C.
4.
Using the screw, secure the add-in card to the riser card bracket. See Letter D. Tighten to 5 in-lb.
Note:
For add-in cards with internal cable connectors, it may be necessary to connect cables before installing
the riser card assembly into the system. See to
Appendix B
for cable routing guidance.
3.3.4
Riser Card Assembly Installation–for All Riser Assemblies
Figure 36. Riser Card Assembly Installation
1.
Position the riser card’s edge connector over the riser slot on the server board.
2.
Align the two key slots on the back edge of the riser card assembly with the mounting keys on the
back of the chassis.
3.
Once aligned, press the riser card assembly straight down into the riser slot (see Letter A).
4.
Using the two static screw heads on the riser bracket, secure the riser card assembly to the server
board (see Letter B).
Tighten to 5 in-lb.
5.
Connect any cables to the add-in card that are required. See your add-in card documentation for
additional information.
6.
Reinstall the system top cover. See
Section 3.1.2
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Page 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...