Intel® Server System M50FCP1UR System Integration and Service Guide
62
6.4
Power Supply Replacement
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
Caution:
The power supply is only hot-swappable (system does not have to be powered down) if the system
has both power supplies installed, and the system is still operational with a single functional power supply.
Figure 72. Power Supply Removal
1.
Detach the power cord from the power supply to be removed.
2.
Push and hold the green latch in the direction shown (see Letter A).
3.
Use the handle to pull the power supply module from the system (see Letter B).
Figure 73. Power Supply Installation
4.
Locate the replacement power supply.
5.
Slide the power supply into the power supply bay until it locks in place (see Letter A).