Intel® Server System M50FCP1UR System Integration and Service Guide
82
6.
Squeeze the two hooks of the internal lock and pull it out (see Letter A).
7.
Align the OCP adapter with the open OCP* bay slot and slide forward until the connectors make
secure contact (see Letter B).
8.
Reinstall the internal lock with the lock orientation (see Letter C).
9.
Reinstall the riser card assembly as needed (see
Section 6.6
10.
Reinstall the system top cover (see
Section 6.1.2
6.10
M.2 Storage Device Replacement
The server board includes two M.2 connectors as shown in the following figure. Each M.2 connector supports
a PCIe* NVMe* or SATA SSD drive that conforms to a 22110 (110 mm) or 2280 (80 mm) form factor.
Required Tools and Supplies
•
Replacement M.2 SSD
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver #1
Figure 113. M.2 SSD Removal
1.
Power off the system and disconnect the system power cords.
2.
Remove the system top cover (see
Section 6.1.1
3.
If installed, remove the riser #1 assembly (see
Section 6.6
).
4.
Locate the M.2 to be replaced.
5.
Remove the screw to release the M.2 SSD from the server board (see Letter A).
6.
Carefully lift the free end of the M.2 SSD and gently remove it from the connector in the direction
shown (see Letter B).
Figure 114. M.2 SSD Installation
7.
Locate and carefully unpack the replacement M.2 SSD. Hold it by its edges.
8.
Depending on the length of the M.2 SSD, use the onboard M.2 mounting stand-off at the appropriate
location.
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Page 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...