Intel® Server System M50FCP1UR System Integration and Service Guide
107
Error Code
Error Message
Action Message
Type
8523
Memory failed test/initialization CPU0_DIMM_B1
Remove the inactivated DIMM.
Major
8524
Memory failed test/initialization CPU0_DIMM_B2
Remove the inactivated DIMM.
Major
8525
Memory failed test/initialization CPU0_DIMM_B3
Remove the inactivated DIMM.
Major
8526
Memory failed test/initialization CPU0_DIMM_C1
Remove the inactivated DIMM.
Major
8527
Memory failed test/initialization CPU0_DIMM_C2
Remove the inactivated DIMM.
Major
8528
Memory failed test/initialization CPU0_DIMM_C3
Remove the inactivated DIMM.
Major
8529
Memory failed test/initialization CPU0_DIMM_D1
Remove the inactivated DIMM.
Major
852A
Memory failed test/initialization CPU0_DIMM_D2
Remove the inactivated DIMM.
Major
852B
Memory failed test/initialization CPU0_DIMM_D3
Remove the inactivated DIMM.
Major
852C
Memory failed test/initialization CPU0_DIMM_E1
Remove the inactivated DIMM.
Major
852D
Memory failed test/initialization CPU0_DIMM_E2
Remove the inactivated DIMM.
Major
852E
Memory failed test/initialization CPU0_DIMM_E3
Remove the inactivated DIMM.
Major
852F
Memory failed test/initialization CPU0_DIMM_F1
Remove the inactivated DIMM.
Major
8530
Memory failed test/initialization CPU0_DIMM_F2
Remove the inactivated DIMM.
Major
8531
Memory failed test/initialization CPU0_DIMM_F3
Remove the inactivated DIMM.
Major
8532
Memory failed test/initialization CPU0_DIMM_G1
Remove the inactivated DIMM.
Major
8533
Memory failed test/initialization CPU0_DIMM_G2
Remove the inactivated DIMM.
Major
8534
Memory failed test/initialization CPU0_DIMM_G3
Remove the inactivated DIMM.
Major
8535
Memory failed test/initialization CPU0_DIMM_H1
Remove the inactivated DIMM.
Major
8536
Memory failed test/initialization CPU0_DIMM_H2
Remove the inactivated DIMM.
Major
8537
Memory failed test/initialization CPU0_DIMM_H3
Remove the inactivated DIMM.
Major
8538
Memory failed test/initialization CPU1_DIMM_A1
Remove the inactivated DIMM.
Major
8539
Memory failed test/initialization CPU1_DIMM_A2
Remove the inactivated DIMM.
Major
853A
Memory failed test/initialization CPU1_DIMM_A3
Remove the inactivated DIMM.
Major
853B
Memory failed test/initialization CPU1_DIMM_B1
Remove the inactivated DIMM.
Major
853C
Memory failed test/initialization CPU1_DIMM_B2
Remove the inactivated DIMM.
Major
853D
Memory failed test/initialization CPU1_DIMM_B3
Remove the inactivated DIMM.
Major
853E
Memory failed test/initialization CPU1_DIMM_C1
Remove the inactivated DIMM.
Major
853F
(Go to 85C0)
Memory failed test/initialization CPU1_DIMM_C2
Remove the inactivated DIMM.
Major
8540
Memory inactivated.CPU0_DIMM_A1
Remove the inactivated DIMM.
Major
8541
Memory inactivated.CPU0_DIMM_A2
Remove the inactivated DIMM.
Major
8542
Memory inactivated.CPU0_DIMM_A3
Remove the inactivated DIMM.
Major
8543
Memory inactivated.CPU0_DIMM_B1
Remove the inactivated DIMM.
Major
8544
Memory inactivated.CPU0_DIMM_B2
Remove the inactivated DIMM.
Major
8545
Memory inactivated.CPU0_DIMM_B3
Remove the inactivated DIMM.
Major
8546
Memory inactivated.CPU0_DIMM_C1
Remove the inactivated DIMM.
Major
8547
Memory inactivated.CPU0_DIMM_C2
Remove the inactivated DIMM.
Major
8548
Memory inactivated.CPU0_DIMM_C3
Remove the inactivated DIMM.
Major
8549
Memory inactivated.CPU0_DIMM_D1
Remove the inactivated DIMM.
Major
854A
Memory inactivated.CPU0_DIMM_D2
Remove the inactivated DIMM.
Major
854B
Memory inactivated.CPU0_DIMM_D3
Remove the inactivated DIMM.
Major
854C
Memory inactivated.CPU0_DIMM_E1
Remove the inactivated DIMM.
Major
854D
Memory inactivated.CPU0_DIMM_E2
Remove the inactivated DIMM.
Major
854E
Memory inactivated.CPU0_DIMM_E3
Remove the inactivated DIMM.
Major
854F
Memory inactivated.CPU0_DIMM_F1
Remove the inactivated DIMM.
Major
8550
Memory inactivated.CPU0_DIMM_F2
Remove the inactivated DIMM.
Major
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Page 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...