background image

1-5-1

120Rj-2

1.5 Model 120Rj-2

MODEL

N8100-1408F

N8100-1409F

N8100-1410F

N8100-1411F

N8100-1440F

N8100-1412F

Dual-Core Intel Xeon

E5205

Dual-Core Intel Xeon

X5260

Quad-Core Intel Xeon

E5405

Quad-Core Intel Xeon

E5420

Quad-Core Intel Xeon

X5450

Quad-Core Intel Xeon

X5460

1.86GHz

3.33GHz

2GHz

2.50GHz

3GHz

3.16GHz

1066MHz

1333MHz

1333MHz

1333MHz

1333MHz

1333MHz

Memory

Standard Capacity

Maximum Capacity

Standard Capacity

Maximum Capacity

Disk Controller
RAID

*6

Hot-Plug

DVD-ROM

Drive

Expansion Slots
[open]

Standard

Optional Riser card

[N8116- 07]
Optional Riser card

[N8116- 08]

* 7

Optional Riser card

[N8116- 18]

Graphics

Dimension
(WxDxH)mm

Power

Maximum

770VA/760W

800VA/ 790W

800VA/790W

800VA/790W

880VA/870W

880VA/870W

637VA/627W

644VA/634W

644VA/634W

644VA/634W

656VA/646W

656VA/646W

Cooling Fan

Full-Height slots
PCI-X (64/133MHz): 1[1], PCI-X (64bit/100MHz): 2[2]

Full-Height slots
PCI Express (x8): 1[1], PCI-X (64bit/100MHz): 2[2]

Low profile slots
 PCI Express (x8): 1[1], PCI Express (x4): 2[1]

*3

Low profile slots
 PCI Express (x8): 1[1], PCI Express (x4): 2[1]

*3

Full-Height slots
PCI-X (64bit/133MHz, 5V): 3[3]

Low profile slots
 PCI Express (x8): 1[1], PCI Express (x4): 2[1]

*3

Full-Height slots
PCI Express (x8): 1[1], PCI Express (x4): 2[2]

Low profile slots
 PCI Express (x8): 1[1], PCI Express (x4): 2[1]

*3

Standard: Not Redundant

Option: Redundant (Hot-plug)

Supported OS
(see chapter of S/W for details)

445 x 722 x 88

485 x 822 x 88 (when front bezel and the protruding objects are included)

Weight

21kg (standard) / 31kg (max.)

Temperature and Humidity Condition

During operation: 10 to 35ºC / 20 to 80% (Non-condensing)

When stored: -10ºC to 55ºC / 20% to 80% (Non-condensing)

*5

Mouse

Option

19inch rack mountable, 2U rack height

Windows Server 2003 Standard Edition (SP1 or later)/ Enterprise Edition (SP1 or later)

Windows Server 2003 R2, Standard Edition / Enterprise Edition

Windows Server 2003 R2, Standard x64 Edition / Enterprise x64 Edition

Red Hat Linux 

*6

External Interface

Serial x2(D-Sub 9pin)(frontx1, rearx1), USB2.0 x6(frontx2, rearx2, internal x2),

1000BASE-T(RJ-45) x2, LAN for Server Management (100BASE-TX, RJ-45) x1,

Display(Mini D-Sub 15pin) x1, Keyboard/Mouse(PS/2) x1

*4

Main unit form

1[1] (3.5-inch)

Power Supply

Standard: 1unit (Not Redundant)

Option: Max. 2 units (Redundant) (Hot-plug)

Remote Management

EXPRESSSCOPE Engine 2 is configured as standard

Keyboard

Option

LAN Interface

1000BASE-T x2 (100BASE-TX and 10BASE-T are supported) (standard)

Integrated in Server Management Controller (8MB)

Disk Drive Bays [open]

6[6] (3.5-inch)

Device Bays [open]

2nd Cache

No. of CPU

CD-RW/DVD-ROM combo drive

*2

 (DVD: x8 max. speed, CD: x24 max. speed)

DDR2-667 FB-DIMM with ECC, x4/x8 SDDC, memory mirror, on-line spare memory

Intel® 64

Supported

Chip set

Front Side Bus

Supported

FDD

Model 120Rj-2

N-code

CPU

Clock

Mandatory option

*1

Internal
HDD

Diskless

SATA: 4.5TB (750GB x6), SAS: 1.8TB (300GB x 6)

When installing 2.5-inch HDD cage [N8154-14F]: SAS 1.172TB (146.5GB x8)

SAS / SATA

6MB

2 x 6MB

48GB (4GB DIMM x12) (when standard DIMMs are removed)

RAID 0,1: Standard

RAID 5,6 : Option (SAS Disk Array Controller is necessary)

1 (standard) - 2 (max.)

Intel 5000P

2GB (1GBx2)

*1Choose one from [N8151-73A] and [N8160-74]. 
*2 Writing software is not supported.
*3 One PCI Express (x4) slot is occupied by RAID controller. 
*4 Keyboard and mouse can use simultaneously by Y cable that is attached to main unit.
*5 When stored at a low or high temperature, the system clock may largely deviate from the current time.
*6 Please refer to “Linux on NEC Express5800” (

http://www.nec.co.jp/express/linux/index.html

)

*7 The optional Riser card [N8116-08] requires more time for shipping because it is Make-to-order product. 

Features

• Quad-Core Xeon E5405/E5420/X5450/X5460 and Dual-Core Xeon E5205/X5260

• DDR2-667 FB-DIMM memory of up to 48GB with ECC, x4/x8 SDDC, memory 

mirroring and on-line spare

• SAS disk drives of up to 1.8TB, SATA disk drives of up to 4.5TB

• RAID controller (RAID0/1) as standard

Summary of Contents for 120Rj-2

Page 1: ...r 2003 R2 Standard x64 Edition Enterprise x64 Edition Red Hat Linux 6 External Interface Serial x2 D Sub 9pin frontx1 rearx1 USB2 0 x6 frontx2 rearx2 internal x2 1000BASE T RJ 45 x2 LAN for Server Management 100BASE TX RJ 45 x1 Display Mini D Sub 15pin x1 Keyboard Mouse PS 2 x1 4 Main unit form 1 1 3 5 inch Power Supply Standard 1unit Not Redundant Option Max 2 units Redundant Hot plug Remote Mana...

Page 2: ...r Serial port UID DUMP USB LAN2 Connector AC Power LED For Mouse Keyboard Switch Switch Connectors Server Management Connector Hard Disk bay Backup device bay Optical disk drive UID LED LAN Access LEDs POWER LED DISK ACCESS LED USB Connectors STATUS LED UID Switch POWER Switch DUMP Switch Serial port Connector FDD bay External Design With standard HDD cage 3 5 inch hard disk drive bays Front View ...

Page 3: ...w Profile Connector Full Height connector Power Supply Option LAN connector Serial port UID DUMP USB LAN2 Connector AC Power LED For Mouse Keyboard Switch Switch Connectors Server Management Connector Hard Disk bay Backup device bay Optical disk drive FDD bay Front View Rear View UID LED LAN Access LEDs POWER LED DISK ACCESS LED USB Connectors STATUS LED UID Switch POWER Switch DUMP Switch Serial ...

Page 4: ...he memory mirroring and on line sparing mode see next page When you use locally procured non NEC memory modules see Chapter 2 Information of Local Procurement Do not use processors of different frequencies at the same time 64GB 64GB 16GB 128GB 32GB 4GB RedHat Enterprise Linux AS4 EM64T RedHat Enterprise Linux AS4 x86 RedHat Enterprise Linux ES4 x86 EM64T Microsoft Windows Server 2003 R2 Enterprise...

Page 5: ... standard memory mode memory mirroring and online spare memory at the same time in the same system Not redundant default Same as physical capacity Not removable during operation Not redundant In the event of a memory failure a spare DIMM takes over a faulty DIMM online A faulty DIMM automatically fails over to a spare memory on the same memory branch Physical capacity does not include spare memory...

Page 6: ...Keyboard N8170 19 cannot be housed in the 19 inch rack cabinet Y cable provided with the main unit Up to eight servers can connect directly to the LCD console unit Use optional Server Switch Units to connect more than eight servers LCD Console Unit A 17 inch LCD keyboard mouse and Server Switch Unit x8 are integrated into the 1U LCD Console Unit 17 inch LCD Console Unit 1U 8port N8143 69F Consists...

Page 7: ...e either a Built in or an External FDD for maintenance and OS installation purpose Automatic System Recovery of Windows Server 2003 operating system and Disaster Recovery Option of backup software are available for both FDD 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 1 CD RW DVD ROM combo drive standard Internal IDE I F Each of the front and rear panels features two USB ports ...

Page 8: ... AIT 1 Turbo 40GB Built In AIT IDE N8151 61A AIT 2 Turbo 80GB Internal IDE Backup Device Internal IDE I F Ultra ATA 100 Internal IDE Backup Device Internal IDE Backup Device Internal SCSI Backup Device Internal SCSI Backup Device Insert into PCI slot SCSI controller SCSI controller N8103 95 Ultra160 SCSI 1ch SCSI controller N8103 107 Ultra320 SCSI 1ch A cable is provided with the main unit Interna...

Page 9: ...traight cable Modem etc RS 232C devices UPS Local procurement One power unit is supplied as standard Another power unit can be added to configure Hot Swap Redundant Power Supply 2 Power Unit Empty slot N8181 49F Power Unit N8181 52 Redundant Fan Fans Empty slots Non redundant fans are supplied as standard The Redundant Fan N8181 52 can be added to configure Hot Swap Redundant Fan Rack mount option...

Page 10: ...e slot as standard PCIe x8 RAID 0 1 128MB cache RAID controller PCIe card installed in as standard RAID Battery Backup Unit N8103 120 Additional DAC Battery HDD Configuration 1 3 5 inch hard disk drives SAS SATA RAID 0 1 Hot Plug 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 Standard HDD Cage 3 5 inch bays Choose one configuration from the varieties below The HDD carriers are NOT required for ...

Page 11: ...Backup Unit N8103 120 Additional DAC Battery N8103 119 RAID Upgrade Kit Requires to support RAID 5 6 HDD Configuration 3 2 5 inch hard disk drives SAS RAID 0 1 Hot Plug 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 Optional HDD Cage N8154 14F 2 5 inch bays Disk bay Disk bay 36 3GB HDD 10 000rpm N8150 219 73 2GB HDD 10 000rpm N8150 220 146 5GB HDD 10 000rpm N8150 228 36 3GB HDD 15 000rpm N8150 ...

Page 12: ...107 at the same time 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 2003 R2 R2x64 EL4 EL4x64 PCI slot N8103 104 SAS controller SATA SAS Disk Array Unit or Device Expansion Unit N8103 90 Disk array controller SAS External External I F Disk Expansion Unit SAS 2003 R2 R2x64 2003 R2 R2x64 N8190 120 Fibre channel controller Fibre Channel Disk Array Unit 1ch 2Gbps optical N8190 127 Fibre channel controller NEC ...

Page 13: ...e 2 with Remote KVM and Media License N8115 03 DianaScope x CUI screen OS console x Panic screen Boot screen Remote console via COM port LAN x HW err Boot err and OS panic by SNMP E Mail via LAN Alerting Monitor booting BIOS POST stall OS stall shutdown Collecting hardware event log Monitor temperature voltage FAN degeneration CPU memory x Stole monitoring Automatic reboot x x Monitoring server No...

Page 14: ...RESS x1 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Disk array controller SAS External PCI EXPRESS x8 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Fibre Channel controller 2Gbps Optical 64bit 133MHz PCI X 10GBASE SR adapter PCI EXPRESS x8 100BASE TX adapter 32bit 33MHz PCI 1000BASE SX adapter 64bit 133MHz PCI X 1000BASE T adapter 2ch PCI EXPRESS x4 1000BASE T adapter PCI EXPRESS...

Page 15: ... Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Fibre Channel controller 2Gbps Optical 64bit 133MHz PCI X 10GBASE SR adapter PCI EXPRESS x8 100BASE TX adapter 32bit 33MHz PCI 1000BASE SX adapter 64bit 133MHz PCI X 1000BASE T adapter 2ch PCI EXPRESS x4 1000BASE T adapter PCI EXPRESS x1 1 Maximum board length Full Height short up to 173 1m...

Page 16: ...S x8 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 N code Full Height Low Profile MD2 Long Short Remarks x8 Socket Optional riser card N8116 18 2 Product name Standard Slots RAID Controller 128MB RAID 0 1 PCI EXPRESS x8 1 Maximum board length Full Height short up to 173 1mm long up to 312mm Low Profile MD1 up to 119 9mm MD2 up to 167 6mm 2 To install optional Riser Cards N8116 07 08 18 rem...

Page 17: ...Standard Configuration with IDE Backup Device Hard Disk Drive SAS SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 RAID Controller Standard RAID Controller Standard Hard Disk Drive SAS SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 Internal IDE Backup Device ...

Page 18: ...SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 Internal SCSI Backup Device Internal SCSI Cable K410 147 00 option SCSI Controller N8103 95 107 4 Standard Configuration with USB Backup Device Requires an Internal USB Cable K410 167 00 to use USB backup device Hard Disk Drive SAS SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 Internal USB Backup Device RAID Controller Standard Internal USB Cab...

Reviews: