background image

1-5-14

120Rj-2

Optional Boards and Adaptable Expansion Slots

Bus  A

Bus  B

Bus  C

Bus  E

PCIe

#1C

PCIe

#2C

PCIe

#3C

PCI-X

#1B

PCI-X

#2B

PCIe

#3B

x8

x4

x4

x8

Slot size

(Full-height or Low Prof ile)

Supported board type

x8

socket

x8

socket

Installable board type 

*1

-

-

-

O

-

-

-

Installed in as standard

N8103-90

-

-

-

-

-

O

Max. 2
N8103-90 cannot connect to the internal HDDs

N8103-95

-

-

-

O

O

-

Max. 3

N8103-75

-

-

-

O

O

-

Max. 3
Do not use with N8103-107

N8103-107

O

O

-

-

-

O

Do not use with N8103-75

N8103-104

O

-

-

-

-

O

Max. 2, not for internal HDD

N8190-120

-

-

-

O

O

-

N8190-127

O

O

-

-

-

O

N8190-131

O

O

-

-

-

O

N8104-111

-

-

-

O

O

-

N8104-119

-

-

-

O

O

-

N8104-120

-

-

-

O

O

-

N8104-126

O

O

-

-

-

O

Max. 2

*4

N8104-121

-

-

-

-

-

O

10BASE-T is not supported.

*5

N8104-122

O

O

-

-

-

-

Max. 2
10BASE-T is not supported

*5

N8104-112

-

-

-

O

O

-

Max. 1 (When configuring AFT teaming, max.2)

*3

N8104-123A

O

-

-

-

-

O

Max. 1

Remarks

SCSI controller
(64bit/133MHz PCI-X)

64bit

100MHz

Bus D

Standard riser card

*2

Product name

SCSI controller
(64bit/66MHz PCI)

3.3V

Standard Slots

RAID Controller (128MB, RAID 0,1)
(PCI EXPRESS (x8))

N code

Full Height

Low Profile

MD2

Long/Short

SAS controller
(PCI EXPRESS(x8))

x4 socket

*3

1000BASE-T adapter
(64bit/133MHz PCI-X)
1000BASE-T adapter (2ch)
(64bit/133MHz PCI-X)

SCSI controller
(PCI EXPRESS(x1))

Fibre Channel controller (4Gbps/Optical)
(PCI EXPRESS(x4))

Disk array controller (SAS, External)
(PCI EXPRESS (x8))

Fibre Channel controller (4Gbps/Optical)
(PCI EXPRESS(x4))

Fibre Channel controller (2Gbps/Optical)
(64bit/133MHz PCI-X)

10GBASE-SR adapter
(PCI EXPRESS(x8))

100BASE-TX adapter
(32bit/33MHz PCI)

1000BASE-SX adapter
(64bit/133MHz PCI-X)

1000BASE-T adapter (2ch)
(PCI EXPRESS(x4))

1000BASE-T adapter
(PCI EXPRESS(x1))

1000BASE-T adapter (2ch)
(PCI EXPRESS(x4))

*1 Maximum board length

Full Height  short: up to 173.1mm   long: up to 312mm
Low Profile MD1: up to 119.9mm   MD2: up to 167.6mm

*2 To install optional Riser Cards [N8116-07/-08/-18], remove the standard riser card. The optional cards are  

mutually exclusive.

*3 Up to one each PCI bus. The 120Rj-2 allows up to two N8104-120 adapters. Do not use the N8104-119/-

120 adapters with the N8104-112 adapter in the same system.

*4 The N8104-126 adapter can be teamed to the identical adapter only (not to other adapters).
*5 Cannot be teamed to other adapters for AFT and ALB. The 120Rj-2 supports up to two adapters

([N8104-121] and/or [N8104-122]).

Note:

• You cannot create an AFT or ALB team across the standard LAN interface and optional LAN board.
• PCI boards with different clock speeds operate at the lowest speed when inserted into the same PCI 

bus.

• You cannot use two or more PCI boards when installing four or more 8GB Memory Module Set 

[N8102-312].

Summary of Contents for 120Rj-2

Page 1: ...r 2003 R2 Standard x64 Edition Enterprise x64 Edition Red Hat Linux 6 External Interface Serial x2 D Sub 9pin frontx1 rearx1 USB2 0 x6 frontx2 rearx2 internal x2 1000BASE T RJ 45 x2 LAN for Server Management 100BASE TX RJ 45 x1 Display Mini D Sub 15pin x1 Keyboard Mouse PS 2 x1 4 Main unit form 1 1 3 5 inch Power Supply Standard 1unit Not Redundant Option Max 2 units Redundant Hot plug Remote Mana...

Page 2: ...r Serial port UID DUMP USB LAN2 Connector AC Power LED For Mouse Keyboard Switch Switch Connectors Server Management Connector Hard Disk bay Backup device bay Optical disk drive UID LED LAN Access LEDs POWER LED DISK ACCESS LED USB Connectors STATUS LED UID Switch POWER Switch DUMP Switch Serial port Connector FDD bay External Design With standard HDD cage 3 5 inch hard disk drive bays Front View ...

Page 3: ...w Profile Connector Full Height connector Power Supply Option LAN connector Serial port UID DUMP USB LAN2 Connector AC Power LED For Mouse Keyboard Switch Switch Connectors Server Management Connector Hard Disk bay Backup device bay Optical disk drive FDD bay Front View Rear View UID LED LAN Access LEDs POWER LED DISK ACCESS LED USB Connectors STATUS LED UID Switch POWER Switch DUMP Switch Serial ...

Page 4: ...he memory mirroring and on line sparing mode see next page When you use locally procured non NEC memory modules see Chapter 2 Information of Local Procurement Do not use processors of different frequencies at the same time 64GB 64GB 16GB 128GB 32GB 4GB RedHat Enterprise Linux AS4 EM64T RedHat Enterprise Linux AS4 x86 RedHat Enterprise Linux ES4 x86 EM64T Microsoft Windows Server 2003 R2 Enterprise...

Page 5: ... standard memory mode memory mirroring and online spare memory at the same time in the same system Not redundant default Same as physical capacity Not removable during operation Not redundant In the event of a memory failure a spare DIMM takes over a faulty DIMM online A faulty DIMM automatically fails over to a spare memory on the same memory branch Physical capacity does not include spare memory...

Page 6: ...Keyboard N8170 19 cannot be housed in the 19 inch rack cabinet Y cable provided with the main unit Up to eight servers can connect directly to the LCD console unit Use optional Server Switch Units to connect more than eight servers LCD Console Unit A 17 inch LCD keyboard mouse and Server Switch Unit x8 are integrated into the 1U LCD Console Unit 17 inch LCD Console Unit 1U 8port N8143 69F Consists...

Page 7: ...e either a Built in or an External FDD for maintenance and OS installation purpose Automatic System Recovery of Windows Server 2003 operating system and Disaster Recovery Option of backup software are available for both FDD 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 1 CD RW DVD ROM combo drive standard Internal IDE I F Each of the front and rear panels features two USB ports ...

Page 8: ... AIT 1 Turbo 40GB Built In AIT IDE N8151 61A AIT 2 Turbo 80GB Internal IDE Backup Device Internal IDE I F Ultra ATA 100 Internal IDE Backup Device Internal IDE Backup Device Internal SCSI Backup Device Internal SCSI Backup Device Insert into PCI slot SCSI controller SCSI controller N8103 95 Ultra160 SCSI 1ch SCSI controller N8103 107 Ultra320 SCSI 1ch A cable is provided with the main unit Interna...

Page 9: ...traight cable Modem etc RS 232C devices UPS Local procurement One power unit is supplied as standard Another power unit can be added to configure Hot Swap Redundant Power Supply 2 Power Unit Empty slot N8181 49F Power Unit N8181 52 Redundant Fan Fans Empty slots Non redundant fans are supplied as standard The Redundant Fan N8181 52 can be added to configure Hot Swap Redundant Fan Rack mount option...

Page 10: ...e slot as standard PCIe x8 RAID 0 1 128MB cache RAID controller PCIe card installed in as standard RAID Battery Backup Unit N8103 120 Additional DAC Battery HDD Configuration 1 3 5 inch hard disk drives SAS SATA RAID 0 1 Hot Plug 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 Standard HDD Cage 3 5 inch bays Choose one configuration from the varieties below The HDD carriers are NOT required for ...

Page 11: ...Backup Unit N8103 120 Additional DAC Battery N8103 119 RAID Upgrade Kit Requires to support RAID 5 6 HDD Configuration 3 2 5 inch hard disk drives SAS RAID 0 1 Hot Plug 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 Optional HDD Cage N8154 14F 2 5 inch bays Disk bay Disk bay 36 3GB HDD 10 000rpm N8150 219 73 2GB HDD 10 000rpm N8150 220 146 5GB HDD 10 000rpm N8150 228 36 3GB HDD 15 000rpm N8150 ...

Page 12: ...107 at the same time 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 2003 R2 R2x64 EL4 EL4x64 PCI slot N8103 104 SAS controller SATA SAS Disk Array Unit or Device Expansion Unit N8103 90 Disk array controller SAS External External I F Disk Expansion Unit SAS 2003 R2 R2x64 2003 R2 R2x64 N8190 120 Fibre channel controller Fibre Channel Disk Array Unit 1ch 2Gbps optical N8190 127 Fibre channel controller NEC ...

Page 13: ...e 2 with Remote KVM and Media License N8115 03 DianaScope x CUI screen OS console x Panic screen Boot screen Remote console via COM port LAN x HW err Boot err and OS panic by SNMP E Mail via LAN Alerting Monitor booting BIOS POST stall OS stall shutdown Collecting hardware event log Monitor temperature voltage FAN degeneration CPU memory x Stole monitoring Automatic reboot x x Monitoring server No...

Page 14: ...RESS x1 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Disk array controller SAS External PCI EXPRESS x8 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Fibre Channel controller 2Gbps Optical 64bit 133MHz PCI X 10GBASE SR adapter PCI EXPRESS x8 100BASE TX adapter 32bit 33MHz PCI 1000BASE SX adapter 64bit 133MHz PCI X 1000BASE T adapter 2ch PCI EXPRESS x4 1000BASE T adapter PCI EXPRESS...

Page 15: ... Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 Fibre Channel controller 2Gbps Optical 64bit 133MHz PCI X 10GBASE SR adapter PCI EXPRESS x8 100BASE TX adapter 32bit 33MHz PCI 1000BASE SX adapter 64bit 133MHz PCI X 1000BASE T adapter 2ch PCI EXPRESS x4 1000BASE T adapter PCI EXPRESS x1 1 Maximum board length Full Height short up to 173 1m...

Page 16: ...S x8 Fibre Channel controller 4Gbps Optical PCI EXPRESS x4 N code Full Height Low Profile MD2 Long Short Remarks x8 Socket Optional riser card N8116 18 2 Product name Standard Slots RAID Controller 128MB RAID 0 1 PCI EXPRESS x8 1 Maximum board length Full Height short up to 173 1mm long up to 312mm Low Profile MD1 up to 119 9mm MD2 up to 167 6mm 2 To install optional Riser Cards N8116 07 08 18 rem...

Page 17: ...Standard Configuration with IDE Backup Device Hard Disk Drive SAS SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 RAID Controller Standard RAID Controller Standard Hard Disk Drive SAS SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 Internal IDE Backup Device ...

Page 18: ...SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 Internal SCSI Backup Device Internal SCSI Cable K410 147 00 option SCSI Controller N8103 95 107 4 Standard Configuration with USB Backup Device Requires an Internal USB Cable K410 167 00 to use USB backup device Hard Disk Drive SAS SATA2 ID 0 1 2 Hard Disk Drive SAS SATA2 ID 3 4 5 Internal USB Backup Device RAID Controller Standard Internal USB Cab...

Reviews: