Intel® Server System M50FCP1UR System Integration and Service Guide
51
5.3
Drive Bay LED Identification
Figure 59. Hot Swap Drive Bay LED Identification
Table 2. Drive Status LED States
Amber
LED State
Drive Status
Off
No access and no fault
Solid on
Hard drive fault has occurred
1 Hz blinking
RAID rebuild in progress
2 Hz blinking
Locate (identify)
Table 3. Drive Activity LED States
Green
Condition
Drive Type
LED Behavior
Power on with no drive activity
SAS/NVMe*
LED stays on
SATA
LED stays off
Power on with drive activity
SAS/NVMe*
LED blinks off when processing a command
SATA
LED blinks on when processing a command
Power on and drive spun down
SAS/NVMe*
LED stays off
SATA
LED stays off
Power on and drive spinning up
SAS/NVMe*
LED blinks
SATA
LED stays off
Note:
The drive activity LED is driven by signals from the drive itself. Drive vendors may choose to operate
the activity LED different from what is described in
. If the activity LED on a given drive type behaves
differently than what is described, customers should reference the drive vendor specifications for the
specific drive model to determine the expected drive activity LED operation.
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Page 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...