Intel® Server System M50FCP1UR System Integration and Service Guide
112
E.2 Processor Initialization Error Summary
The following table describes mixed processor conditions and actions for all Intel® server boards and Intel®
server systems designed with the Intel® Xeon® Scalable processor family architecture. The errors fall into one
of the following categories:
•
Fatal
: The system halts with a halt error code on the diagnostic LEDs and a corresponding sequence
consisting of three long flashes and one short flash is sent to the POST Error Code LED. The system
cannot boot unless the error is resolved. The faulty component must be replaced.
•
Major
: If the BIOS Setup option “POST Error Pause” is enabled, the system goes directly to the BIOS
Setup Error Manager to display the error and logs the POST error code to SEL. User intervention is
required to continue booting the system. If the BIOS Setup option “POST Error Pause” is disabled, the
system continues to boot and no prompt for the error is given, although the POST error code is
logged to the BIOS Setup Error Manager and to the SEL.
•
Minor: An error message may be displayed to the screen or to the BIOS Setup Error Manager screen
and the POST error code is logged to the SEL. The system continues booting in a degraded state. The
user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup
utility does not affect this error.
Table 15. Mixed Processor Configurations Error Summary
Error
Severity
System Action when BIOS Detects the Error Condition
Processor family
not identical
Fatal
Halts with error code “0xE5” on the diagnostic LED.
Sends three long flashes and one short flash to the POST Error LED.
Does not boot until the fault condition is remediated.
Processor model
not identical
Fatal
Halts with error code “0xE5” on the diagnostic LED.
Sends three long flashes and one short flash to the POST Error LED.
Does not boot until the fault condition is remediated.
Processor cache or
home agent not
identical
Fatal
Halts with error code “0xE5” on the diagnostic LED.
Sends three long flashes and one short flash to the POST Error LED.
Does not boot until the fault condition is remediated.
Processor
frequency (speed)
not identical
Fatal
Halts with error code “0xE5” on the diagnostic LED.
Sends three long flashes and one short flash to the POST Error LED.
Does not boot until the fault condition is remediated.
Processor
Intel® UPI link
frequencies not
identical
Fatal
Halts with error code “0xE5” on the diagnostic LED.
Sends three long flashes and one short flash to the POST Error LED.
Does not boot until the fault condition is remediated.
Processor
microcode update
failed
Major
Logs the POST error code “81 6x” into the SEL.
If the “POST Error Pause” is enabled in the BIOS Setup, loads the BIOS Error Manager to
present error message “816x: Processor 0x unable to apply microcode update” on the
screen.
If the “POST Error Pause” is disabled in the BIOS Setup continues to boot in a degraded
state.
Processor
microcode update
missing
Minor
•
Logs the POST error code “81 8x” into the SEL.
•
The system continues to boot in a degraded state, regardless of the “POST Error Pause”
setting in the BIOS setup.
•
The Error Manager in BIOS Setup will present the message “818x: Processor microcode
update not found”
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...