Intel® Server System M50FCP1UR System Integration and Service Guide
86
Figure 119. 4 x 2.5” Backplane Installation
7.
Locate and carefully unpack the replacement backplane.
Note:
Hold the backplane by its edges. Do not touch any components mounted to the backplane.
8.
Align and lower the bottom edge of the backplane with the three tabs on the chassis base. See
9.
Verify the alignment of the three backplane mounting holes with the threaded studs of the front drive
bay.
10.
Secure the backplane with three screws as shown (see Letter B).
11.
Re-attach all cables to the backplane.
12.
Reinstall all drives and/or drive blanks into the front drive bay.
Notes:
•
All front drive bays must be populated with an SSD or supplied drive blank.
•
If the front drives were configured as part of a RAID partition, ensure that all drive I/O cables and
drives were reinstalled to the same locations as they were configured before the procedure.
13.
Reinstall the system top cover (see
Section 6.1.2
).
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Page 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...