Intel® Server System M50FCP1UR System Integration and Service Guide
31
3.
System Options / Accessory Kit Installation
This chapter provides instructions for the integration of system options and other Intel accessories. If your
integrated Intel server system did not come preinstalled with processors, memory, or power supplies,
installation procedures for these components are in
Chapter 2
.
Before You Begin
Before integration of any system components, review all the safety and ESD precautions found in the Safety
Warnings section at the beginning of this document.
System Reference
In the following procedures, all references to left, right, front, top, and bottom assume that the reader is
facing the front of the server chassis.
Instruction Format
Each procedure described in this chapter follows an illustration first format. This format gives the reader the
option to follow a quicker path to component integration by first seeing an illustration of the intended
procedure. If necessary, the reader can then follow the step-by-step instructions that accompany each
procedure.
3.1
System Top Cover Removal / Installation
The system top cover consists of two panels, one over the front half of the system, and one over the back
half of the system. To maintain system thermals, both top cover panels must be in place when the system is
operational.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver #1
3.1.1
System Cover Removal
Removal of both top cover panels is necessary when servicing any system component in the server chassis.
Before removing the top cover, power down the system and unplug all peripheral devices and system power
cords.
Figure 24. System Top Cover Panel Shipping Screws
The system ships from the factory with the front cover panel and back cover panel screwed to the chassis. A
total of four screws, one on each side of the front cover panel and one on each side of the back cover panel,
need to be removed to detach both top cover panels from the chassis.
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Page 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Page 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...