INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
Position Terminal no.,
Description
Function
3
N-FK
4
N-FK
5
FKL
Car light; switched by relay KF5 (output A5)
6
L_FK
Car light power, monitoring of car light (input E28, 110V / 230V AC)
7
L_FK
8
VEN
Car ventilator, switched by relay KF6 (output A6)
XF17
1
SKK
Trailing cable, safety circuit to car
2
SKF
Trailing cable, safety circuit behind safety gear
3
SKI
Trailing cable, safety circuit behind inspection
4
SKD
Trailing cable, safety circuit behind revolving door
5
SKT
Trailing cable, safety circuit behind car door
6
SKZ
Trailing cable, safety circuit behind inspection for door zone bypass
7
N_FK
Trailing cable, neutral of car light power supply
8
L_FL
Trailing cable, car light power supply, monitored by input E28 (110V / 230V
AC)
9
Res.
Trailing cable, free wire, onboard connected to XF9.3
XF18
Connector for Software download
XF19
Only
FVE1.1
1
+24V
Connector for additional inspection relay; onboard connected to XF12.6
2
IE
XF20
Only
FVE1.1
1
Frei
Mini-DIN connector for handheld terminal (CAN-Bus, battery buffered 24V
power supply)
2
Frei
3
C-
4
0(24V)
5
C+
6
+24A
XF20
Only
FVE2.1
1
+24A
Connector for handheld terminal (CAN-Bus, battery buffered 24V power
supply)
2
0(24V)
3
C+
4
C-
XF21
Modul 1
Slot 1 for connecting a UEA to power supply and CAN bus
For configuration see description of Jumper XFJ1
XF22
Modul 2
Slot 1 for connecting a UEA to power supply and CAN bus
For configuration see description of Jumper XFJ2
LED
LED “Software is running”
Technical specifications:
Temperature range:
0
°
C to +60
°
C
Max. power consumption by 24V:
<
200mA @ 25
°
C (all relays and in-/outputs active)
Max. input current 24V inputs:
10mA @ 25
°
C / Input
Max. current KF1 to KF6:
8A/250V AC / Relay
Max. output current A9-16
500mA @ 25
°
C / Output
Max. input current 230V DC input(car light):
10mA @ 25
°
C, 230VAC, 50Hz
Mechanical dimensions:
Length:
225mm
Width:
130mm