![Intec MLC 8000 Operating Manual Download Page 170](http://html1.mh-extra.com/html/intec/mlc-8000/mlc-8000_operating-manual_2070494170.webp)
INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
Height:
ca. 40mm
Characteristics and features:
The module FVE is designed as an intelligent distribution board for use on the car roof or in the car
operation panel COP. Therefore several distribution terminals are located on the FVE, which means
no additional terminals are required normaly on top of car car or in the car operation panel COP.
- PIC18-Microcontroller with integrated Flash memory (32kByte), RAM (1536 Byte) and EEPROM
(256 Byte)
- integrated CAN bus controller
- CAN interface with high speed driver according to ISO11898 with galvanic isolation
- Supervision input for car light power (110V / 230V AC, 50 / 60 Hz), galvanic isolated
- Relay for switching off car light
- Relay for car ventilator
- ICSP interface for In-Circuit programming (Software download)
- 8 Inputs and 8 Outputs, always 1 input and 1 output connected together onboard (lowside active)
- 18 free programmable digital inputs (lowside active)
- 4 free programmable relays
- 4-layer PCB with internal power layers
- integated emergency light output (max. 800 mA)
- integrated alarm relay with 1 changeover contact (only Hardware version 2.1)
- connector for handheld terminal (hardware version 1.1: Mini-DIN connector, Adapter cable
necessary)
Appendix 1.4 Module FVE 1.2
Position Terminal no.
Description
Function
XFJ1
Setting the power supply mode for UEA board connected to right slot (XF22):
-
Jumper set to the top: normal 24V power supply
XF8
XF7
XF6
XF5
XF4
XF3
XF2
XF1
XF16
XF15
XF14
XF13
XF12
XF11
XF10
XF9
XF17
XF18
XF19
XF20
XF21
XF22
XF23
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
XFJ2
XFJ1
XFJ6
XF
J3
X
F
J5
X
F
J4
LED
KF5
KF6
KF7
KF4
KF3
KF2
KF1