Lift controller MLC 8000
Operating manual V2.0
104/196
Nr.
Error message
Description
Lift controller reaction
error or after inspection trip).
176/112 OP device err.
Faulty condition of the OP
device (e.g. set both limit
switches)
Back to normal operation if OP
device has defined state again.
176/113 OP device ramp
OP-device is unlocked while
the lift wants to start
See above
176/114 OP dev. not out
OP device can't move out
See above
176/115 OP dev. not in
OP device can't move in
See above
176/116 OP dev. ramp on
Ramp of OP device can't move
out
See above
176/117 OP dev. ramp off
Ramp of OP device can't move
in
See above
176/128 Uncontr.movement
Lift moved out of the door zone
while the doors are open
(see EN81 Annex A3)
Out of operation.
Back to normal operation only by
operationg a special Reset switch
or by switching on emergency
recall operation.
176/129 Input unc.move
Lift controller has recognized
uncontrolled movement, but the
input to check the uncontrolled
movement state has not
switched on.
Out of operation.
Back to normal operation only by
operationg a special Reset switch
or by switching on emergency
recall operation.
176/131 No deceleration
Lifts with slow down control
circuit: Lift didn't slow down to
defined speed at the final floors
Emergency stop
Back to normal operation after a
few seconds.
176/132 Dec.circ.not off
Lifts with slow down control
circuit: Control circuit still
triggered at standstill
Back to normal operation if control
circuit has right state again
176/144 LIMAX Floortab
If using LIMAX Safe as
positioning system: Position
difference between LIMAX
Safe and HSE
Emergency stop
New setup procedure necessary
176/145 LIMAX Insp.sig
If using LIMAX Safe as
positioning system: Inspection
signal inputs of LIMAX Safe
wrong
Check wiring of LIMAX Safe
176/146 LIMAX Relay test
If using LIMAX Safe as
positioning system: The cyclic
relay test takes unusually too
long
Check LIMAX Safe; if this occurs
repeatedly,change LIMAX
192/1
Trip time out
Time between 2 state changes
of shaft switches SGM (door
zone) exceeded (Trip time
monitoring according to EN81;
parameter "Triptime[s]").
Emergency stop, out of operation
192/2
LS or callmisuse
Number of trips on car calls, in
which the light screen has not
been interrupted, exceeded
All car calls cleared; no further
error reaction