INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
125/196
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
Clock run 2
-
-
Input to start clock runs.
More settings see „Special param." – "Clock run" and also "Door releases"
Clock run 3
-
-
See above
Clock run 4
-
-
See above
Clock run 5
-
-
See above
Safety beam
-
-
Safety beam for lift without car door
Earthquake
-
-
Earthquake sensor input (lift is switched off immediately)
Auto-call
-
-
Starting the autocall function
More parameter see „Special param." – "Auto-call funct."
- Up peak
- Dn peak
-
-
Inputs for lifts with high traffic: During up peak (down peak) the lift only serves
landing calls in up direction (down direction) and ignores the landing calls in
opposite direction.
Note: This function may be activated by this input as well as with the internal
timer function (see "Group control")
Final limit
-
-
Additional contact on final limit switch to check, if the final limit switch is
opened.
Em.stop
Signal no.
-
Emergency stop push operated (2 contact additional to contact in safety circuit)
With setting "Signal no." it is possible to connect different emergency stop
pushes (e.g. emergency stop pit, ememergency stop inspection, ...) to the lift
controller.
Note: The same signal no. should not exist more than 1 time in a lift.
Phase error
-
-
Contact from phase relay
AWG2 err.
Signal no.
Error signal from AWG2 evaluation unit (POS2) if the "Double-AWG" is used for
positioning
By using the signal no. (1 and 2) the error signal may be connected twice for
safety reasons (the evaluation board POS2 has 2 error outputs - 1 standard and 1
inverted)
Insp.limit
Direction
-
Input for inspection limit switch
Service mode
-
-
In service mode only Inspection, Emergency recall operation and travel
commands from keypad may be used, otherwise lift is out of operation.
Insp.Reset
-
-
Reset button input to return back from inspection pit mode
SL bypass
Signal no.
-
Safety circuit car or shaft door shorted (according to EN81-20) - lift only moves
now with recall operation or inspection.