Temperature range:
0
°
C to +60
°
C
Max. current for LED @ 24V:
ca. 100 mA
Max. current alarm call relay:
1 A
Max. voltage alarm call relay:
125V AC / 120 V DC
Mechanical dimensions:
see picture
Height:
ca. 25mm (without connector)
Appendix 1.9 Module CBK
Position
Pin
Function
XG1
1
+24V
+24V Power supply input
2
0(24V)
0V Power supply input
XG2
1
0(24V)
0V Power supply; connector for cable shield
2
C2+
CAN bus High signal (CAN bus to HSE)
3
C2-
CAN bus Low signal (CAN bus to HSE)
4
C2+
See above
5
C2-
See above
XG3
1
0(24V)
0V Power supply; connector for cable shield
2
C5+
CAN bus High signal (CAN bus to shaft)
3
C5-
CAN bus Low signal (CAN bus to shaft)
XH1
Connector for Software download
XG1
Pin1
Pin1
Pin1
XG3
XH1
Pin1
JP2
JP1
LED5
LED4
LED1
LED3
LED2
SW1
DIP1
XG2