INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
Position Terminal no.
Description
Function
3
KF1/2
Common for N.O. contact relays KF1 and KF2
4
GND
Input E4 and 0V power supply, free programmable, default: Light screen
door 1
5
EF4
6
GND
Input E3 and 0V power supply, free programmable, default: Reverse switch
door 1 (mechanical obstacle)
7
EF3
8
GND
Input E2 and 0V power supply, free programmable, default: Door closed
limit switch door 1
9
EF2
10
GND
Input E1 and 0V power supply, free programmable, default: Door opened
limit switch door 1
11
EF1
XF14
1
GND
Input E18 and 0V power supply, free programmable, default: Overload
signal
2
EF18
XF15
1
CHA
Connectors for incremental encoder channel A and B (direct connected to
XF1.7+8)
2
CHB
3
+24A
Battery bu24V power supply for incremental encoder
4
GND
0V power supply for incremental encoder
XF16
1
GND
Connectors for analog load sensor and power 24V, sensor signal
see Jumper XFJ4+5 above
2
In
3
+24V
XF17
1
Res1
Free connectors for additional trailing cable wires; onboard connected to
XF17.Res1-3
2
Res2
3
Res3
XF18
1
+24A
Battery buffered 24V power supply for Position unit KLST GmbH (flat cable)
2
SM
Door zone switch SGM of Position unit KLST GmbH (flat cable)
3
SU
Inputs E25, E24, E26, E27 (low active), for door zone switches SGU and
SGO and for prelimit switches VO and VU (Position unit KLST GmbH over
flat cable)
4
SO
5
VO
6
VU
7
0(24V)
0V power supply for Position unit KLST GmbH (flat cable)
8
0(24V)
9
+24V
24V power supply for Position unit KLST GmbH (flat cable)
10
+24V
XF19
1
NR
Alarm call car operation panel COP (for flat cable connection of COP)
2
EAF10
7 Inputs/Outputs E10-E16 and A10-A16
Low active, mainly for car operation panel COP (for flat cable connection of
COP)
Note: Inputs/outputs are also available on connector XF11
3
EAF11
4
EAF12
5
EAF13
6
EAF14
7
EAF15
8
EAF16
9
GND
0V – power supply for car operation panel COP (for flat cable connection of
COP)
10
+24V
+24V power supply for car operation panel COP (for flat cable connection of
COP)
11
NL
Emergency light in car operation panel COP (FVE output A7, for flat cable
connection of COP)
12
+24A
Battery bu24V power supply for car operation panel COP (for flat
cable connection of COP)
13
M
Intercom microphone (for flat cable connection of COP)
14
L
Intercom loudspeaker (for flat cable connection of COP)
XF20
1
NR
Alarm call car operation panel COP, flat cable to TVE
2
EAF9
8 Inputs/Outputs E9-E16 and A9-A16
Low active, mainly for car operation panel COP (flat cable to TVE)
3
EAF10