Lift controller MLC 8000
Operating manual V2.0
24/196
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Description
speed v2
Min.Dist.v1
Minimum distance between start and target floor to start with reduced
speed v1
Min.Dist.vZ2
Minimum distance between start and target floor to start with reduced
speed vZ2
Min.Dist.vZ1
Minimum distance between start and target floor to start with reduced
speed vZ1
Dec. vI
↑
Braking distance for inspection speed vI in the upward direction
Dec. vI
↓
Braking distance for inspection speed vI in the downward direction
Stop vI
↑
Stopping distance for inspection speed in the upward direction
Stop vI
↓
Stopping distance for inspection speed in the downward direction
Stop vN
↑
Stopping distance for relevelling speed in the upward direction
Stop vN
↓
Stopping distance for relevelling speed in the downward direction
Stop vAh
Stopping distance if moving with vAh in upward direction (lift with
holding bolts
Stop vAs
Stopping distance if moving with vAs in downward direction (lift with
holding bolts
Floor positions
Floor distances
Distance between 2 floors
Fl. 1- 2
Fl. 2- 3
…
Floor height
Absolute floor position
1.Floor
B ottom floor = 0
2.Floor
…
SGM Positionen
Measured switching points of the door zone switch SGM
1.Floor
↑
switching point above 1st floor
1.Floor
↓
switching point below 1st floor
2.Floor
↑
…