51/196
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Description
Dec.extens.
↓
See above; for downwards direction
Car fan
Fan mode
autom.: The cabin fan is switched on automatically at the trip start and
switched off at trip end with a time delay (see next parameter).
manual: The cabin fan is turned on and off with a fan switch. By this
setting, a max. duration (see the next parameter) can be programmed.
Time [s]
At automatic fan mode (see above): Time delay before switching off
the fan after every trip.
At manual fan mode :maximum switched on time. If the time is set to
0, then the fan is not switched off automatically.
Interm.door
While moving
yes: intermediate door is monitored while moving. If this intermediate
door opens while moving, the lift will clear all calls and stops in the
next floor. At the same time, an error message is set in the error stack.
no: intermediate door is monitored only during standstill.
Car display
Settings for the car level display
Overload
Indicates, if overload should be displayed at the landing. At a level
indicator inside the car overload is always displayed.
Non-smoke CC
Specifies , whether the "Non smoking sign" is displayed on the level
display inside car (currently only available on LCD display LCI16)
Non-smoke LC
Specifies , whether the "Non smoking sign" is displayed on the level
display at the landings (currently only available on LCD display LCI16)
Inspection
Indicates whether the inspection state and emergency recall operation
state to be displayed on the indicator.
Out of order
Specifies whether to display "Out of order" on the indicator
Fault
Specifies whether to display a fault state on the indicator
Buzzer
Function of the integrated buzzer on some level indicators:
- Load: Buzzer sounds in case of overload
- Door: buzzer sounds during forced door closing (light screen
ignored)
- Car call: buzzer sounds briefly as an acoustic car call indication
Any combination of these 3 functions are possible
Targ.dist.
Specifies at what distance before floor level (in mm), the level display
is switched to the nexgt floor.
If this parameter is set to 0, level display switches to next floor at 2/3
of the distance between this floors.
Gong