![Intec MLC 8000 Operating Manual Download Page 43](http://html1.mh-extra.com/html/intec/mlc-8000/mlc-8000_operating-manual_2070494043.webp)
INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
43/196
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Description
Doors
Setting the car doors which should remain open after the lift is remote
switched off.
Carlight off
yes: In Remote shutdown the car light is switched off, even if not all
car doors are closed.
no: Car light will stay on in Remote shutdown mode
Clear calls
yes: If the remote shutdown input is activated all calls are cleared and
disabled immediately.
no: If the Remote off function is activated, all saved calls are still
handled, but new calls are not accepted. If all old calls are handled, the
lift will be switched off.
Lift off-doors
Specifies the doors which shall remain open in each floor when the lift
has been turned off by the special function "Lift off" (see section Input
Functions)
Floor 1
Doors which will remain open after the lift was turned off on the 1st
floor
Floor 2
Doors which will remain open after the lift was turned off on the 2nd
floor
...
...
Safety Beam
Parameter for Safety beam
Safety beam
Safety beam available (yes/no)
Clear CC
Clear all car calls if safety beam is interrupted while lift is moving
(yes/no)
Saf.Reset LC
Resetting the safety beam with landing possible call (yes / no)
Saf.beam SL
Safety beam connected in the safety line (during safety circuit
interruption error "light beam" is indicated).
Sicherheitslichtgitter im Sicherheitskreis (bei Unterbrechung
Singcherheitskreis erscheint Fehler „Lichtgitter“
Safety Shelter
Parameter for safety shelter monitoring
Bearer
↑
Bearer type for safety shelter in shaft top:
No: No bearer necessary / available
manual: hand operated bearer
always: The bearer is always switched on in normal operation and
only switched off when the top shelter space is opened (e.g. by
opening shaft door in top floor) or the inspection control is switched
on.
moving: The bearer is switched on while the lift is moving (but not if