1. Menu level
2. Menu level
3. Menu level
4. Menu level
Description
Since AWG2 and POS2 are on a separate CAN -Bu , the module test
can only be performed when the CAN bus is connected to the control
bus (on which also the HSE is connected) or can be connected via
relay (the relay is switched through special output "CAN-AWG").
Example:
POS2: 1.02
AWG2: ---
In the example the CAN bus connection wokrs well to POS2, the
software version of POS2 is 1.02.
The CAN bus connection to AWG2 is interrupted or AWG2 is defective.
Doors
Doors module test (CANopen doors)
Example:
Door1: ok
Door2: (FVE)
The example indicates that door 1 is controlled via CAN open (see
more details by pressing ENTER). Door 2 is controlled by inputs and
outputs directly through the FVE (no further action by pressing
ENTER).
Example:
Door1: AT40
HW:Rev.01
SW:V01.25
Display of the door type as well as the hardware and software version
of door controller.
Load measurement
Menu is only available if a load measurement device with CAN bus
connection is used
Example:
MCAN
HW:V1.0
SW:V1.0
163 kg
1st line: Name of the load measurement unit
2nd Line: Current Software Version of the load measurement unit
3rd Line: Current Hardware version of the load measurement unit
4th line: Actual load value
Modem/Ethernet
Hardware test Onboard module (Ethernet/Modem)
Example:
Ethernet
1st line: module type
2
nd
line: Last command to the module
3rd line left: Modem state
3rd line right: Monitoring time