INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
144/196
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
Pos.
- SGM
- SGO
- SGU
- VO
- VU
- SGV
- SGE
-
-
Position output functions to simulate magnetic switches (for travel
simulation and testing purposes only).
Car light
-
-
-
Output funtion to switch off the car light if the lift is not used.
See "Timer parameter" -> „Carlight off [s]“.
As default relay KF5 of FVE is used for this function, because this
relay is already wired with the car light supply.
Door output
Door opening
(Floor)
Doors
Output for door opening.
The setting "Floor" is only available if the output function is
programmed for an ESE board, e.g. for controlling an electric
operated shaft door.
Door closing
(Floor)
Doors
Output for door closing.
The setting "Floor" is only available if the output function is
programmed for an ESE board, e.g. for controlling an electric
operated shaft door.
Door nudging
(Floor)
Doors
Output for door nudging (Light screen ignored).
RetiringRamp
(Floor)
Doors
Output to control the door ramp
Add.Ramp
(Floor)
Doors
Output to control an additional door ramp which must be on if the
door is moving.
Emerg.light
-
-
-
Emergency light output.
As default output A7 of FVE is used for emergency light; in general
every other output may be used as emergency light output, as long
as this PCB is battery power supplied (+24A).
Car sensor
- Door 1
- Door 2
- Door 3
- Middle
-
-
Output to display if the vehicle is rigth in the middle of the lift cabin
or if it is still to closed at a door (sensor at this door still
interrupted; see input function "Cae sensor".
Traffic lift
- Red
Floor
Doors
Traffic light output on doors of a vehicle lift (car lift).