![Intec MLC 8000 Operating Manual Download Page 193](http://html1.mh-extra.com/html/intec/mlc-8000/mlc-8000_operating-manual_2070494193.webp)
INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
Position
Pin
Function
XL1
1
+24V
+24V Power supply input
2
0(24V)
0V Power supply input
3
CAN+
CAN-Bus – High signal
4
CAN-
CAN-Bus – Low signal
XL2
1
0(24V)
0V Power supply for inputs / outputs
2
3
4
5
6
7
8
9
D1
D2
D3
D4
D5
D6
D7
D8
8 inputs / outputs E1-E8 and A1-A8, low active, free programmable.
Connector XL2 is in parallel to XL3 (same inputs/outputs)
10
+24V
+24V Power supply for inputs / outputs
XL3
1
2
3
4
5
6
7
8
D1
D2
D3
D4
D5
D6
D7
D8
8 inputs / outputs E1-E8 and A1-A8, low active, free programmable.
Connector XL3 is in parallel to XL2 (same inputs/outputs)
9
0(24V)
0V Power supply for inputs / outputs
10
+24V
+24V Power supply for inputs / outputs
XL4
1
KT1C
Alarm relay common
2
KT1O
N.C. contact
3
KT1S
N.O. contact
XL5
1
+24A
Connector for handheld terminal (battery buffered 24V power supply)
2
0(24V)
Connector for handheld terminal (0V power supply)
3
CH+
Connector for handheld terminal (CAN bus high signal)
4
CH-
Connector for handheld terminal (CAN bus high signal)
XL6
Flat cable connection to FVE Version 1.2 (see description of FVE 1.2, connector XF20
1
NR
Alarm call
2
EAF9
8 connected inputs / outputs of FVE (E9-E16 and A9-A16
0V switching)
Connector 2 (EAF9) is connected with the onboard buzzer of LCD-057
3
EAF10
4
EAF11
5
EAF12
6
EAF13
7
EAF14
8
EAF15
9
EAF16
10
+24A
Battery buffered 24V power
11
+24V
+24V power
12
GND
0V power
13
+24V
+24V power
14
NL
Emergency light car operation panel COP (from output A7 FVE)
15
+24A
Battery buffered 24V power
16
M
Intercom microphone
17
L
Intercom loudspeaker
18
CH+
CAN-Bus – High signal
19
CH-
CAN-Bus – Low signal
20
GND
0V power