Nr.
Error message
Description
Lift controller reaction
- Frequently switching inputs
- Errors in the controller
software
129/100 No conn. to COP
No CAN bus data transmission
to TSE boards inside car
operation panel COP.
Possible reasons:
- TSE defective
- COP not connected
- CAN bus line disturbed
Lift continues operation.
Internal test of data transmission
129/128 Overrun RS232
Data overflow on RS232
interface (too much incoming
data in short time)
129/129 Offl.Err.RS232
Disturbing signals on RS232 in
offline mode
129/130 Onl.Err.RS232
Disturbing signals on RS232 in
online mode
129/131 CRC error RS232
Invalid data received (wrong
checksum) on RS232
129/144 Overrun iModul
Data overflow on iModul
(Modem, Ethernet, ...)
129/145 Offl.Err.iModul
Disturbing signals on iModul
(Modem, Ethernet, ...) in offline
mode
129/146 Onl.Err.iModul
Disturbing signals on iModul
(Modem, Ethernet, ...) in online
mode
129/147 CRC error iModul
Invalid data received (wrong
checksum) on iModul
(Modem, Ethernet, ...)
130/48 Mult. group no.
There are 2 HSE modules with
the same group number in a lift
group
The lift continues, however,
landing calls and group control do
not work properly.
144/1
Min.pressure
For hydraulic lifts: oil pressure
below the limit (input
"Min.pressure" activated).
Emergency stop.
Back to normal operation if input is
deactivated again.
144/2
Max.pressure
For hydraulic lifts: oil pressure
above the limit (input
"Max.pressure" activated).
Emergency stop.
Back to normal operation if input is
deactivated again.
144/16 Overload
Lift overloaded
Only measured if lift is located in a
floor with open doors.
Back to normal operation if
overload input is off.
160/0
Drive error
Fault signal from the drive at
standstill state.
Error state.
Back to normal operation if fault
signal is deactivated.
161/0
Drive err.move
Fault signal from the drive
while moving.
Emergency stop.
Back to normal operation if fault
signal is deactivated.