![Intec MLC 8000 Operating Manual Download Page 72](http://html1.mh-extra.com/html/intec/mlc-8000/mlc-8000_operating-manual_2070494072.webp)
INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
72/196
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Description
repeated several times for individual floors. It only must be ensured
that each floor is measured at least once.
Travel commands
Here, the menu "Travel commands" can be called, with which the
individual floors can be reached (see also description of "Travel
commands" above).
As an alternative to this menu item the individual floors can also be
reached by inspection or emergency control.
Act.floor
Measure floor
After a floor has been reached (deviation should not be more than
50mm; The more precisely, the easier the flush correction is done
later), the number of the current floor is entered in first line.
Subsequently, with the item "Measure position" , the current position
is stored.
Set reference
Setting of the reference point for the absolute encoder.
Note: If the absolute encoder or the magnetic tape of the ELGO
position system must be changed (by a defect), it is only necessary to
set the reference point again (as long as the resolution of the absolute
encoder did not change).
Act.floor
Set reference
To input the reference point , the lift is moved as accurately as
possible to any floor. Then the current floor is entered from the
keyboard in the 1st line, the cursor is then placed in the 2nd row and
by pressing ENTER, the reference point is set.
Brake distances
See above "Brake distances" by incremental encoder
Flush correction
See above "Flush correction" by incremental encoder
via COP
See above
Via terminal
See above
Sub menus if Positioning system with LIMAX Safe
Highest position
To start setup procedure for LIMAX Safe the final limit positions must
be entered. For this the LIMAX safe must be put by long pressing the
button on the device in the calibration mode (the Limax safe then
beeps every second). Then the lift must be moved with emergency
recall operationto the upper or lower end position and the value is
stored using these menu items. Only after setting the final limit
positions the Limax safe closes the safety circuit and the lift can be
moved via hand-held terminal or inspection control.
Lowest position
Floor positions
See above setting "Floor positions" by absolute encoder
...